Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional

Interim Semester 2020/2021

Saved in:
Bibliographic Details
Main Author: Muhammad Irfan Syahmi bin Mohd Anuar
Format: text::Thesis
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-21670
record_format dspace
spelling my.uniten.dspace-216702023-05-04T13:41:47Z Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional Muhammad Irfan Syahmi bin Mohd Anuar indoor Air Quality UNITEN Interim Semester 2020/2021 This study assessed the physical and chemical parameters related to indoor air quality (IAQ) in UNITEN and the IAQ of selected campus buildings were compared with guidelines provided by DOSH. A comparison of the IAQ of the selected buildings before and after the implementation of the Movement Control Order (MCO) were also conducted. This study is especially important as students spend most of their time indoors thus making them more vulnerable to exposure to indoor contaminants. Seven sampling locations around the UNITEN campus were selected which all have different structural layout. The indoor contaminants were recorded using real-time monitoring method and the parameters of interest are the Carbon Monoxide (CO), Particulate Matter (PM2.5 and PM10), Total Volatile Organic Compound (TVOC), relative humidity and temperature. Results show that the overall IAQ level in UNITEN is at a safe level as it is well below the DOSH permissible limit. Statistical analysis also shows that there was no significant difference in IAQ level between all sampling locations (P≤0.05). The comparison for Pre-MCO and Post-MCO also showed that there was no significant difference statistically which also mean that occupancy rate has little effect on the IAQ levels. 2023-05-03T17:37:05Z 2023-05-03T17:37:05Z 2020-09 Resource Types::text::Thesis https://irepository.uniten.edu.my/handle/123456789/21670 application/pdf
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic indoor Air Quality UNITEN
spellingShingle indoor Air Quality UNITEN
Muhammad Irfan Syahmi bin Mohd Anuar
Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional
description Interim Semester 2020/2021
format Resource Types::text::Thesis
author Muhammad Irfan Syahmi bin Mohd Anuar
author_facet Muhammad Irfan Syahmi bin Mohd Anuar
author_sort Muhammad Irfan Syahmi bin Mohd Anuar
title Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional
title_short Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional
title_full Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional
title_fullStr Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional
title_full_unstemmed Investigation of Indoor Air Quality (Iaq): A Case Study in Universiti Tenaga Nasional
title_sort investigation of indoor air quality (iaq): a case study in universiti tenaga nasional
publishDate 2023
_version_ 1806424030772723712
score 13.222552