Investigate the noise exposure in UNITEN

The source of noise in UNITEN can be clearly heard at chiller, AHU unit, centrifugal fan blower and laboratory equipment which may affect human hearing and cause disturbance to nearby areas. This study examines the permissible noise exposure limit for each of the noise sources as per Department of S...

Full description

Saved in:
Bibliographic Details
Main Author: Muhamad Syahmi Bin Johari
Format:
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-21596
record_format dspace
spelling my.uniten.dspace-215962023-05-05T05:14:41Z Investigate the noise exposure in UNITEN Muhamad Syahmi Bin Johari Noise exposure Permissible noise exposure limit Noise reduction The source of noise in UNITEN can be clearly heard at chiller, AHU unit, centrifugal fan blower and laboratory equipment which may affect human hearing and cause disturbance to nearby areas. This study examines the permissible noise exposure limit for each of the noise sources as per Department of Safety and Health (DOSH) and Department of Environment (DOE) requirements. The allowable working duration for each of the noise sources was allocated as a safety guidance for the workers. In estimating the level of disturbance, the anticipated community annoyance response was determined. Meanwhile, for noise reduction strategy, the necessary changes in approach taken to reduce the noise exposure level were recommended. The data of equivalent continuous sound pressure level, LAeq were measured at 26 working areas using sound level meter. The findings showed that 20 working areas had excessive noise level which were greater than the noise exposure limit. A total of 40 noise sources had been specified with allowable working duration according to 16 hours A-weighted noise exposure limit. Besides, the anticipated community annoyance response resulted a maximum level which was a very strong impact to the community. The recommended approaches to reduce the noise exposure were suggested which were an acoustic enclosure for pump and chiller, silencer for AHU unit, spring isolator for concrete vibration table and an acoustic absorber for centrifugal fan blower. In summary, the noise exposure in UNITEN was clearly investigated which may be useful for implementing the noise reduction in future works. KEYWORDS: noise exposure, sound pressure level, noise source, permissible noise exposure limit, noise reduction, UNITEN. 2023-05-03T17:22:30Z 2023-05-03T17:22:30Z 2020-02 https://irepository.uniten.edu.my/handle/123456789/21596 application/pdf
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Noise exposure
Permissible noise exposure limit
Noise reduction
spellingShingle Noise exposure
Permissible noise exposure limit
Noise reduction
Muhamad Syahmi Bin Johari
Investigate the noise exposure in UNITEN
description The source of noise in UNITEN can be clearly heard at chiller, AHU unit, centrifugal fan blower and laboratory equipment which may affect human hearing and cause disturbance to nearby areas. This study examines the permissible noise exposure limit for each of the noise sources as per Department of Safety and Health (DOSH) and Department of Environment (DOE) requirements. The allowable working duration for each of the noise sources was allocated as a safety guidance for the workers. In estimating the level of disturbance, the anticipated community annoyance response was determined. Meanwhile, for noise reduction strategy, the necessary changes in approach taken to reduce the noise exposure level were recommended. The data of equivalent continuous sound pressure level, LAeq were measured at 26 working areas using sound level meter. The findings showed that 20 working areas had excessive noise level which were greater than the noise exposure limit. A total of 40 noise sources had been specified with allowable working duration according to 16 hours A-weighted noise exposure limit. Besides, the anticipated community annoyance response resulted a maximum level which was a very strong impact to the community. The recommended approaches to reduce the noise exposure were suggested which were an acoustic enclosure for pump and chiller, silencer for AHU unit, spring isolator for concrete vibration table and an acoustic absorber for centrifugal fan blower. In summary, the noise exposure in UNITEN was clearly investigated which may be useful for implementing the noise reduction in future works. KEYWORDS: noise exposure, sound pressure level, noise source, permissible noise exposure limit, noise reduction, UNITEN.
format
author Muhamad Syahmi Bin Johari
author_facet Muhamad Syahmi Bin Johari
author_sort Muhamad Syahmi Bin Johari
title Investigate the noise exposure in UNITEN
title_short Investigate the noise exposure in UNITEN
title_full Investigate the noise exposure in UNITEN
title_fullStr Investigate the noise exposure in UNITEN
title_full_unstemmed Investigate the noise exposure in UNITEN
title_sort investigate the noise exposure in uniten
publishDate 2023
_version_ 1806427609969459200
score 13.188404