Mechanichal Porperies of Boiler Tubes ( T91 AND T92)

In this modern days, there are plenty of reasons for failure of boiler tubes in power plant in Malaysia. One of the main concern is the material use as boiler tube and it’s mechanical properties. T91 and T92 is a ferritic-martensite alloy steel. This material has a good tensile strength and good mec...

Full description

Saved in:
Bibliographic Details
Main Author: Kalairasan A /l Anparassan
Format:
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-21369
record_format dspace
spelling my.uniten.dspace-213692023-05-04T17:22:53Z Mechanichal Porperies of Boiler Tubes ( T91 AND T92) Kalairasan A /l Anparassan Mechanical properties Boiler tubes In this modern days, there are plenty of reasons for failure of boiler tubes in power plant in Malaysia. One of the main concern is the material use as boiler tube and it’s mechanical properties. T91 and T92 is a ferritic-martensite alloy steel. This material has a good tensile strength and good mechanical properties. This material has been used as boiler tube at several power plant. Due to some reasons, this material became a failure as the boiler easily tend to crack or break. So, the mechanical properties of the boiler tube were tested. The tests which were conducted were tensile test, hardness testing and microstructure analysis using etching process. Tensile test was done using Zwick universal tester in which it gives the Modulus strength and the value of ultimate strength (MPa). By using that, the shear-strain graph was obtained. Hardness test where done using Brinell method as it is the best method to get the HB value of the materials. It’s about the penentration depth and force applied. As for the microstructure analysis, it was done using etching process. The etchant used was Nital Etch since it is most suitable etchant to be used for this material. It was found that T92 has greater ultimate strength value which is 450MPa compare to T91. As for the hardness test, T92 is stronger, has greater HB value compare to T91. The HB value of T92 is 233 whereas the HB value for T91 is 221. The microstructure analysis was done and it was clearly observed since it was done grinding, polishing and etching process. The carbide and precipitates were clearly seen. In terms of mechanical properties, T91 and T91 has good mechanical properties since they have strong ultimate strength and also both has a strong HB values. 2023-05-03T16:42:26Z 2023-05-03T16:42:26Z 2020-02 https://irepository.uniten.edu.my/handle/123456789/21369 application/pdf
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Mechanical properties
Boiler tubes
spellingShingle Mechanical properties
Boiler tubes
Kalairasan A /l Anparassan
Mechanichal Porperies of Boiler Tubes ( T91 AND T92)
description In this modern days, there are plenty of reasons for failure of boiler tubes in power plant in Malaysia. One of the main concern is the material use as boiler tube and it’s mechanical properties. T91 and T92 is a ferritic-martensite alloy steel. This material has a good tensile strength and good mechanical properties. This material has been used as boiler tube at several power plant. Due to some reasons, this material became a failure as the boiler easily tend to crack or break. So, the mechanical properties of the boiler tube were tested. The tests which were conducted were tensile test, hardness testing and microstructure analysis using etching process. Tensile test was done using Zwick universal tester in which it gives the Modulus strength and the value of ultimate strength (MPa). By using that, the shear-strain graph was obtained. Hardness test where done using Brinell method as it is the best method to get the HB value of the materials. It’s about the penentration depth and force applied. As for the microstructure analysis, it was done using etching process. The etchant used was Nital Etch since it is most suitable etchant to be used for this material. It was found that T92 has greater ultimate strength value which is 450MPa compare to T91. As for the hardness test, T92 is stronger, has greater HB value compare to T91. The HB value of T92 is 233 whereas the HB value for T91 is 221. The microstructure analysis was done and it was clearly observed since it was done grinding, polishing and etching process. The carbide and precipitates were clearly seen. In terms of mechanical properties, T91 and T91 has good mechanical properties since they have strong ultimate strength and also both has a strong HB values.
format
author Kalairasan A /l Anparassan
author_facet Kalairasan A /l Anparassan
author_sort Kalairasan A /l Anparassan
title Mechanichal Porperies of Boiler Tubes ( T91 AND T92)
title_short Mechanichal Porperies of Boiler Tubes ( T91 AND T92)
title_full Mechanichal Porperies of Boiler Tubes ( T91 AND T92)
title_fullStr Mechanichal Porperies of Boiler Tubes ( T91 AND T92)
title_full_unstemmed Mechanichal Porperies of Boiler Tubes ( T91 AND T92)
title_sort mechanichal porperies of boiler tubes ( t91 and t92)
publishDate 2023
_version_ 1806425717315993600
score 13.223943