Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side)

FYP 2 SEM 2 2019/2020

Saved in:
Bibliographic Details
Main Author: Amirah Binti Husaini
Format:
Language:English
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-21360
record_format dspace
spelling my.uniten.dspace-213602023-05-04T15:06:13Z Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side) Amirah Binti Husaini Surge Arrester FYP 2 SEM 2 2019/2020 Lightning surges can be produced on overhead transmission lines either through shielding failures or through back-flashovers. Shielding failure occurs when lightning strikes directly at a phase conductor bypassing the overhead shielding wires. Since higher magnitude of lightning currents are more likely to terminate on the grounded shield wires, shielding failures are typically from low magnitude lightning currents. Back-flashovers, on the other hand, occur when lightning strikes the shielding shield wires or the tower structure and the resulting voltage developing on the tower from its impedance causes a flashover across the line insulation. Surges from back-flashovers are significantly higher in magnitude than those from shielding failures and have very steep fronts, therefore it is more dangerous to the substation equipment. For this reason, in this project, only surges from back-flashovers are considered. Often, lightning related flashover risks from shielding failures and back-flashovers are indicated by Shielding Failure Flashover Rate (SFFOR) and Back-Flashover Rate (BFR), respectively. This project requires research and evaluation of the ideal location of the surge arrester and the number of surge arrester that is needed to be install inside the 132kV substation in order to overcome the lightning overvoltage and optimize the substation performance. In addition, identify the magnitude of overvoltage that may be imposed on the substation equipment’s from lightning surges and assess the adequacy of the insulation withstand capability of the installed equipment to the lightning overvoltage. 2023-05-03T16:41:01Z 2023-05-03T16:41:01Z 2020-02 https://irepository.uniten.edu.my/handle/123456789/21360 en application/pdf
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
topic Surge Arrester
spellingShingle Surge Arrester
Amirah Binti Husaini
Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side)
description FYP 2 SEM 2 2019/2020
format
author Amirah Binti Husaini
author_facet Amirah Binti Husaini
author_sort Amirah Binti Husaini
title Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side)
title_short Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side)
title_full Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side)
title_fullStr Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side)
title_full_unstemmed Optimization Of Surge Arrester's Placement For 132kV Substation(Transmission Side)
title_sort optimization of surge arrester's placement for 132kv substation(transmission side)
publishDate 2023
_version_ 1806424365459308544
score 13.222552