Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan

FYP 2 SEM 1 2019 / 2020

Saved in:
Bibliographic Details
Main Author: Abdullah Ehsan Roslan
Format: text
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-20591
record_format dspace
spelling my.uniten.dspace-205912023-12-05T16:13:00Z Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan Abdullah Ehsan Roslan Rate of dust accumulation Cross- flow fan Staggered angle FYP 2 SEM 1 2019 / 2020 In this study, the rate of dust accumulation in an existing cross-flow fan and the effect of staggered angle on the rate of dust accumulation were investigated. Staggered angles for existing cross-flow fan and two new design of cross-flow fan were selected as the investigation parameter. An existing cross-flow fan was studied to identify parameters involve in designing new designs with different staggered angle. Three cross-flow fans were designed using CAE software, SolidWorks as 3D printer were used to develop prototypes. In addition, an experiment was conducted to test all prototypes. To perform all of these experiments in a relatively short time, small size models were design. Results were evaluated based on output parameters which were mass of cross-flow fan and rate of dust accumulation on cross-flow fan or mass flow rate. As the results of the study, overall mass flow rates for three models were obtained and presented. The result was analyzed and discussed to obtain new design of cross-flow fan that has lower rate of dust accumulation. This research would be useful for other researcher to produce more effective and efficient cross-flow fan. 2023-05-03T15:07:15Z 2023-05-03T15:07:15Z 2019-10 Resource Types::text https://irepository.uniten.edu.my/handle/123456789/20591 application/pdf
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Rate of dust accumulation
Cross- flow fan
Staggered angle
spellingShingle Rate of dust accumulation
Cross- flow fan
Staggered angle
Abdullah Ehsan Roslan
Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan
description FYP 2 SEM 1 2019 / 2020
format Resource Types::text
author Abdullah Ehsan Roslan
author_facet Abdullah Ehsan Roslan
author_sort Abdullah Ehsan Roslan
title Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan
title_short Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan
title_full Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan
title_fullStr Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan
title_full_unstemmed Design Improvement of a Wall - mounted Air Conditioning Unit Cross - flow Fan
title_sort design improvement of a wall - mounted air conditioning unit cross - flow fan
publishDate 2023
_version_ 1806424169107161088