Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks

Ferroresonance is a nonlinear phenomenon that damages the undesired, destructive system for energy transmission lines. The formation and development of this overvoltage ferroresonance phenomenon is an important research topic as a mysterious event in energy power systems. In this study, Seyit Omer...

Full description

Saved in:
Bibliographic Details
Main Authors: Omer Akgun, Tahir Cetin Akıncı, Gokhan Erdemir, Serhat Seker
Format: Article
Language:English
Published: 2020
Subjects:
Online Access:http://dspace.uniten.edu.my/jspui/handle/123456789/13404
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-13404
record_format dspace
spelling my.uniten.dspace-134042020-02-06T04:30:28Z Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks Omer Akgun Tahir Cetin Akıncı Gokhan Erdemir Serhat Seker Hilbert-Huang transform Ferroresonance Spectrograms Instantaneous frequency Instantaneous phase Ferroresonance is a nonlinear phenomenon that damages the undesired, destructive system for energy transmission lines. The formation and development of this overvoltage ferroresonance phenomenon is an important research topic as a mysterious event in energy power systems. In this study, Seyit Omer-Iklar energy transmission line from Turkey’s electrical transmission networks was modelled using real parameters. Ferroresonance scenario was created on the model. The energy transmission system with the scenario is set to a simulation time of 4 seconds. The first two seconds are set to normal. By cutting off the transmission line in the 2nd sec., the system is provided with ferroresonance drift. According to the data obtained therefrom, spectrograms, instantaneous amplitude, instantaneous frequency and instantaneous phase were conducted. The analyses have made clear that the instantaneous frequency amplitude defined the system’s ferroresonance moment very well. 2020-02-06T04:30:27Z 2020-02-06T04:30:27Z 2019 Article http://dspace.uniten.edu.my/jspui/handle/123456789/13404 en Journal of Electrical Engineering
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
topic Hilbert-Huang transform
Ferroresonance
Spectrograms
Instantaneous frequency
Instantaneous phase
spellingShingle Hilbert-Huang transform
Ferroresonance
Spectrograms
Instantaneous frequency
Instantaneous phase
Omer Akgun
Tahir Cetin Akıncı
Gokhan Erdemir
Serhat Seker
Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
description Ferroresonance is a nonlinear phenomenon that damages the undesired, destructive system for energy transmission lines. The formation and development of this overvoltage ferroresonance phenomenon is an important research topic as a mysterious event in energy power systems. In this study, Seyit Omer-Iklar energy transmission line from Turkey’s electrical transmission networks was modelled using real parameters. Ferroresonance scenario was created on the model. The energy transmission system with the scenario is set to a simulation time of 4 seconds. The first two seconds are set to normal. By cutting off the transmission line in the 2nd sec., the system is provided with ferroresonance drift. According to the data obtained therefrom, spectrograms, instantaneous amplitude, instantaneous frequency and instantaneous phase were conducted. The analyses have made clear that the instantaneous frequency amplitude defined the system’s ferroresonance moment very well.
format Article
author Omer Akgun
Tahir Cetin Akıncı
Gokhan Erdemir
Serhat Seker
author_facet Omer Akgun
Tahir Cetin Akıncı
Gokhan Erdemir
Serhat Seker
author_sort Omer Akgun
title Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
title_short Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
title_full Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
title_fullStr Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
title_full_unstemmed Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
title_sort analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
publishDate 2020
url http://dspace.uniten.edu.my/jspui/handle/123456789/13404
_version_ 1662758857034694656
score 13.211869