Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks
Ferroresonance is a nonlinear phenomenon that damages the undesired, destructive system for energy transmission lines. The formation and development of this overvoltage ferroresonance phenomenon is an important research topic as a mysterious event in energy power systems. In this study, Seyit Omer...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | http://dspace.uniten.edu.my/jspui/handle/123456789/13404 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-13404 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-134042020-02-06T04:30:28Z Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks Omer Akgun Tahir Cetin Akıncı Gokhan Erdemir Serhat Seker Hilbert-Huang transform Ferroresonance Spectrograms Instantaneous frequency Instantaneous phase Ferroresonance is a nonlinear phenomenon that damages the undesired, destructive system for energy transmission lines. The formation and development of this overvoltage ferroresonance phenomenon is an important research topic as a mysterious event in energy power systems. In this study, Seyit Omer-Iklar energy transmission line from Turkey’s electrical transmission networks was modelled using real parameters. Ferroresonance scenario was created on the model. The energy transmission system with the scenario is set to a simulation time of 4 seconds. The first two seconds are set to normal. By cutting off the transmission line in the 2nd sec., the system is provided with ferroresonance drift. According to the data obtained therefrom, spectrograms, instantaneous amplitude, instantaneous frequency and instantaneous phase were conducted. The analyses have made clear that the instantaneous frequency amplitude defined the system’s ferroresonance moment very well. 2020-02-06T04:30:27Z 2020-02-06T04:30:27Z 2019 Article http://dspace.uniten.edu.my/jspui/handle/123456789/13404 en Journal of Electrical Engineering |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
topic |
Hilbert-Huang transform Ferroresonance Spectrograms Instantaneous frequency Instantaneous phase |
spellingShingle |
Hilbert-Huang transform Ferroresonance Spectrograms Instantaneous frequency Instantaneous phase Omer Akgun Tahir Cetin Akıncı Gokhan Erdemir Serhat Seker Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks |
description |
Ferroresonance is a nonlinear phenomenon that damages the undesired, destructive system for energy transmission lines.
The formation and development of this overvoltage ferroresonance phenomenon is an important research topic as a mysterious
event in energy power systems. In this study, Seyit Omer-Iklar energy transmission line from Turkey’s electrical transmission
networks was modelled using real parameters. Ferroresonance scenario was created on the model. The energy transmission
system with the scenario is set to a simulation time of 4 seconds. The first two seconds are set to normal. By cutting off the
transmission line in the 2nd sec., the system is provided with ferroresonance drift. According to the data obtained therefrom,
spectrograms, instantaneous amplitude, instantaneous frequency and instantaneous phase were conducted. The analyses have
made clear that the instantaneous frequency amplitude defined the system’s ferroresonance moment very well. |
format |
Article |
author |
Omer Akgun Tahir Cetin Akıncı Gokhan Erdemir Serhat Seker |
author_facet |
Omer Akgun Tahir Cetin Akıncı Gokhan Erdemir Serhat Seker |
author_sort |
Omer Akgun |
title |
Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks |
title_short |
Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks |
title_full |
Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks |
title_fullStr |
Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks |
title_full_unstemmed |
Analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks |
title_sort |
analysis of instantaneous frequency, instantaneous amplitude and phase angle of ferroresonance in electrical power networks |
publishDate |
2020 |
url |
http://dspace.uniten.edu.my/jspui/handle/123456789/13404 |
_version_ |
1662758857034694656 |
score |
13.222552 |