Impact of high penetration of solar pv output to line loading, voltage and power losses
This paper presents the impact of high penetration of solar photovoltaic (PV) power plant to the grid on the line loading, voltage and power losses. In this study, the simulation works is done for IEEE 30 bus test system using Power System Simulation for Engineers (PSSE) software with and without so...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2020
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-13307 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-133072020-07-03T05:14:05Z Impact of high penetration of solar pv output to line loading, voltage and power losses Kamil, K. Chong, K.H. Hashim, H. This paper presents the impact of high penetration of solar photovoltaic (PV) power plant to the grid on the line loading, voltage and power losses. In this study, the simulation works is done for IEEE 30 bus test system using Power System Simulation for Engineers (PSSE) software with and without solar PV integration. Simulation results show that high PV penetration of solar PV output causes higher line loading, introduce voltage variation and power losses in the network which might disturb the performance of the network. © 2019, World Academy of Research in Science and Engineering. All rights reserved. 2020-02-03T03:31:43Z 2020-02-03T03:31:43Z 2019 Article 10.30534/ijatcse/2019/5381.62019 en |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
description |
This paper presents the impact of high penetration of solar photovoltaic (PV) power plant to the grid on the line loading, voltage and power losses. In this study, the simulation works is done for IEEE 30 bus test system using Power System Simulation for Engineers (PSSE) software with and without solar PV integration. Simulation results show that high PV penetration of solar PV output causes higher line loading, introduce voltage variation and power losses in the network which might disturb the performance of the network. © 2019, World Academy of Research in Science and Engineering. All rights reserved. |
format |
Article |
author |
Kamil, K. Chong, K.H. Hashim, H. |
spellingShingle |
Kamil, K. Chong, K.H. Hashim, H. Impact of high penetration of solar pv output to line loading, voltage and power losses |
author_facet |
Kamil, K. Chong, K.H. Hashim, H. |
author_sort |
Kamil, K. |
title |
Impact of high penetration of solar pv output to line loading, voltage and power losses |
title_short |
Impact of high penetration of solar pv output to line loading, voltage and power losses |
title_full |
Impact of high penetration of solar pv output to line loading, voltage and power losses |
title_fullStr |
Impact of high penetration of solar pv output to line loading, voltage and power losses |
title_full_unstemmed |
Impact of high penetration of solar pv output to line loading, voltage and power losses |
title_sort |
impact of high penetration of solar pv output to line loading, voltage and power losses |
publishDate |
2020 |
_version_ |
1672614221803683840 |
score |
13.2400255 |