Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm
Severe lightning overvoltage is regarded to the multiple flashovers on the overhead lines. Therefore, it signifies the needs of having a robust insulation system, especially to those which highly susceptible to lightning strikes. In order to minimize the impact of lightning, it is necessary to evalu...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Paper |
Language: | English |
Published: |
2020
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-13006 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-130062020-07-07T01:47:41Z Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm Abd Rahman, M.S. Ab Kadir, M.Z.A. Ab-Rahman, M.S. Osman, M. Nor, S.F.M. Severe lightning overvoltage is regarded to the multiple flashovers on the overhead lines. Therefore, it signifies the needs of having a robust insulation system, especially to those which highly susceptible to lightning strikes. In order to minimize the impact of lightning, it is necessary to evaluate lightning performance of the tower and its components before implementing any proposed design. Therefore, in this work, a feasibility study was done on proposed 275 kV and 132 kV transmission tower with composite crossarm installed. In order to assess the insulation strength of the tower against the lightning activities, lightning caused events i.e. backflashover and shielding failure were applied onto the tower models by using FEM based software. The CFO of the tower insulation were calculated based on the design provided, whereby it was complementary verified by the voltage and electric field profiles of the simulation. For each case, none had shown a voltage magnitude higher than the voltage supposed to possibly cause 50% chance of flashover. © 2019 IEEE. 2020-02-03T03:28:27Z 2020-02-03T03:28:27Z 2019 Conference Paper 10.1109/APL.2019.8816041 en |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
description |
Severe lightning overvoltage is regarded to the multiple flashovers on the overhead lines. Therefore, it signifies the needs of having a robust insulation system, especially to those which highly susceptible to lightning strikes. In order to minimize the impact of lightning, it is necessary to evaluate lightning performance of the tower and its components before implementing any proposed design. Therefore, in this work, a feasibility study was done on proposed 275 kV and 132 kV transmission tower with composite crossarm installed. In order to assess the insulation strength of the tower against the lightning activities, lightning caused events i.e. backflashover and shielding failure were applied onto the tower models by using FEM based software. The CFO of the tower insulation were calculated based on the design provided, whereby it was complementary verified by the voltage and electric field profiles of the simulation. For each case, none had shown a voltage magnitude higher than the voltage supposed to possibly cause 50% chance of flashover. © 2019 IEEE. |
format |
Conference Paper |
author |
Abd Rahman, M.S. Ab Kadir, M.Z.A. Ab-Rahman, M.S. Osman, M. Nor, S.F.M. |
spellingShingle |
Abd Rahman, M.S. Ab Kadir, M.Z.A. Ab-Rahman, M.S. Osman, M. Nor, S.F.M. Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
author_facet |
Abd Rahman, M.S. Ab Kadir, M.Z.A. Ab-Rahman, M.S. Osman, M. Nor, S.F.M. |
author_sort |
Abd Rahman, M.S. |
title |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_short |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_full |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_fullStr |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_full_unstemmed |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_sort |
lightning impulse strength of 275 kv and 132 kv tower with composite crossarm |
publishDate |
2020 |
_version_ |
1672614198457139200 |
score |
13.222552 |