Geomagnetic induced current measurement in hybrid PV-wind system transformers
Geo magnetically induced currents (GICs) can cause saturation of the magnetic core of transformers in a power system. This saturation can conduce to generating harmonic currents, voltage-control problems and overheating of the transformer internal components, leading to gas relay alarm/operation and...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2020
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-12794 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-127942020-08-25T04:20:45Z Geomagnetic induced current measurement in hybrid PV-wind system transformers Khurshid, Z.M. Aziz, N.F.A. Kadir, M.Z.A.A. Rhazali, Z.A. Geo magnetically induced currents (GICs) can cause saturation of the magnetic core of transformers in a power system. This saturation can conduce to generating harmonic currents, voltage-control problems and overheating of the transformer internal components, leading to gas relay alarm/operation and possible damage. In this work, GICs effects have been analyzed on hybrid PV-wind system transformers. The system implemented through using Power System Computer Aided Design (PSCAD/EMTDC) platform and made up of 2.1 MW wind farm, 2 MW solar photovoltaic (PV) farm, power storage system and load. Then the system is integrated with 33 kV grids through a 480V AC bus and step-up wye/delta transformer. In addition, Pi-section has been used between different parts of the system. The GIC is modeled as a controlled DC voltage source and inserted into the system through a neutral point of a wind turbine (WT) transformer. The simulation results of reactive power, voltage and current waveforms, and non-linear behavior due to asymmetric saturation of the magnetic core in the transformer due to 100 A GIC current injections are obtained. Moreover, different GIC blocking devices have been applied to mitigate or eliminate the flow of GIC to the system. © BEIESP. 2020-02-03T03:26:52Z 2020-02-03T03:26:52Z 2020-04 Article 10.35940/ijrte.D5148.118419 en |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
description |
Geo magnetically induced currents (GICs) can cause saturation of the magnetic core of transformers in a power system. This saturation can conduce to generating harmonic currents, voltage-control problems and overheating of the transformer internal components, leading to gas relay alarm/operation and possible damage. In this work, GICs effects have been analyzed on hybrid PV-wind system transformers. The system implemented through using Power System Computer Aided Design (PSCAD/EMTDC) platform and made up of 2.1 MW wind farm, 2 MW solar photovoltaic (PV) farm, power storage system and load. Then the system is integrated with 33 kV grids through a 480V AC bus and step-up wye/delta transformer. In addition, Pi-section has been used between different parts of the system. The GIC is modeled as a controlled DC voltage source and inserted into the system through a neutral point of a wind turbine (WT) transformer. The simulation results of reactive power, voltage and current waveforms, and non-linear behavior due to asymmetric saturation of the magnetic core in the transformer due to 100 A GIC current injections are obtained. Moreover, different GIC blocking devices have been applied to mitigate or eliminate the flow of GIC to the system. © BEIESP. |
format |
Article |
author |
Khurshid, Z.M. Aziz, N.F.A. Kadir, M.Z.A.A. Rhazali, Z.A. |
spellingShingle |
Khurshid, Z.M. Aziz, N.F.A. Kadir, M.Z.A.A. Rhazali, Z.A. Geomagnetic induced current measurement in hybrid PV-wind system transformers |
author_facet |
Khurshid, Z.M. Aziz, N.F.A. Kadir, M.Z.A.A. Rhazali, Z.A. |
author_sort |
Khurshid, Z.M. |
title |
Geomagnetic induced current measurement in hybrid PV-wind system transformers |
title_short |
Geomagnetic induced current measurement in hybrid PV-wind system transformers |
title_full |
Geomagnetic induced current measurement in hybrid PV-wind system transformers |
title_fullStr |
Geomagnetic induced current measurement in hybrid PV-wind system transformers |
title_full_unstemmed |
Geomagnetic induced current measurement in hybrid PV-wind system transformers |
title_sort |
geomagnetic induced current measurement in hybrid pv-wind system transformers |
publishDate |
2020 |
_version_ |
1678595884992954368 |
score |
13.222552 |