Geomagnetic induced current measurement in hybrid PV-wind system transformers

Geo magnetically induced currents (GICs) can cause saturation of the magnetic core of transformers in a power system. This saturation can conduce to generating harmonic currents, voltage-control problems and overheating of the transformer internal components, leading to gas relay alarm/operation and...

Full description

Saved in:
Bibliographic Details
Main Authors: Khurshid, Z.M., Aziz, N.F.A., Kadir, M.Z.A.A., Rhazali, Z.A.
Format: Article
Language:English
Published: 2020
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-12794
record_format dspace
spelling my.uniten.dspace-127942020-08-25T04:20:45Z Geomagnetic induced current measurement in hybrid PV-wind system transformers Khurshid, Z.M. Aziz, N.F.A. Kadir, M.Z.A.A. Rhazali, Z.A. Geo magnetically induced currents (GICs) can cause saturation of the magnetic core of transformers in a power system. This saturation can conduce to generating harmonic currents, voltage-control problems and overheating of the transformer internal components, leading to gas relay alarm/operation and possible damage. In this work, GICs effects have been analyzed on hybrid PV-wind system transformers. The system implemented through using Power System Computer Aided Design (PSCAD/EMTDC) platform and made up of 2.1 MW wind farm, 2 MW solar photovoltaic (PV) farm, power storage system and load. Then the system is integrated with 33 kV grids through a 480V AC bus and step-up wye/delta transformer. In addition, Pi-section has been used between different parts of the system. The GIC is modeled as a controlled DC voltage source and inserted into the system through a neutral point of a wind turbine (WT) transformer. The simulation results of reactive power, voltage and current waveforms, and non-linear behavior due to asymmetric saturation of the magnetic core in the transformer due to 100 A GIC current injections are obtained. Moreover, different GIC blocking devices have been applied to mitigate or eliminate the flow of GIC to the system. © BEIESP. 2020-02-03T03:26:52Z 2020-02-03T03:26:52Z 2020-04 Article 10.35940/ijrte.D5148.118419 en
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
description Geo magnetically induced currents (GICs) can cause saturation of the magnetic core of transformers in a power system. This saturation can conduce to generating harmonic currents, voltage-control problems and overheating of the transformer internal components, leading to gas relay alarm/operation and possible damage. In this work, GICs effects have been analyzed on hybrid PV-wind system transformers. The system implemented through using Power System Computer Aided Design (PSCAD/EMTDC) platform and made up of 2.1 MW wind farm, 2 MW solar photovoltaic (PV) farm, power storage system and load. Then the system is integrated with 33 kV grids through a 480V AC bus and step-up wye/delta transformer. In addition, Pi-section has been used between different parts of the system. The GIC is modeled as a controlled DC voltage source and inserted into the system through a neutral point of a wind turbine (WT) transformer. The simulation results of reactive power, voltage and current waveforms, and non-linear behavior due to asymmetric saturation of the magnetic core in the transformer due to 100 A GIC current injections are obtained. Moreover, different GIC blocking devices have been applied to mitigate or eliminate the flow of GIC to the system. © BEIESP.
format Article
author Khurshid, Z.M.
Aziz, N.F.A.
Kadir, M.Z.A.A.
Rhazali, Z.A.
spellingShingle Khurshid, Z.M.
Aziz, N.F.A.
Kadir, M.Z.A.A.
Rhazali, Z.A.
Geomagnetic induced current measurement in hybrid PV-wind system transformers
author_facet Khurshid, Z.M.
Aziz, N.F.A.
Kadir, M.Z.A.A.
Rhazali, Z.A.
author_sort Khurshid, Z.M.
title Geomagnetic induced current measurement in hybrid PV-wind system transformers
title_short Geomagnetic induced current measurement in hybrid PV-wind system transformers
title_full Geomagnetic induced current measurement in hybrid PV-wind system transformers
title_fullStr Geomagnetic induced current measurement in hybrid PV-wind system transformers
title_full_unstemmed Geomagnetic induced current measurement in hybrid PV-wind system transformers
title_sort geomagnetic induced current measurement in hybrid pv-wind system transformers
publishDate 2020
_version_ 1678595884992954368
score 13.222552