Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions

This paper proposes an improved hierarchical control strategy consists of a primary and a secondary layer for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions. The primary layer is comprised of a multi-loop control strategy to provide balanced output voltages, a harmonic...

Full description

Saved in:
Bibliographic Details
Main Authors: Naderipour, A., Abdul-Malek, Z., Ramachandaramurthy, V.K., Kalam, A., Miveh, M.R.
Format: Article
Language:English
Published: 2020
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-12792
record_format dspace
spelling my.uniten.dspace-127922020-07-07T08:41:43Z Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions Naderipour, A. Abdul-Malek, Z. Ramachandaramurthy, V.K. Kalam, A. Miveh, M.R. This paper proposes an improved hierarchical control strategy consists of a primary and a secondary layer for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions. The primary layer is comprised of a multi-loop control strategy to provide balanced output voltages, a harmonic compensator to reduce the total harmonic distortion (THD), and a droop-based scheme to achieve an accurate power sharing. At the secondary control layer, a reactive power compensator and a frequency restoration loop are designed to improve the accuracy of reactive power sharing and to restore the frequency deviation, respectively. Simulation studies and practical performance are carried out using the DIgSILENT Power Factory software and laboratory testing, to verify the effectiveness of the control strategy in both islanded and grid-connected mode. Zero reactive power sharing error and zero frequency steady-state error have given this control strategy an edge over the conventional control scheme. Furthermore, the proposed scheme presented outstanding voltage control performance, such as fast transient response and low voltage THD. The superiority of the proposed control strategy over the conventional filter-based control scheme is confirmed by the 2 line cycles decrease in the transient response. Additionally, the voltage THDs in islanded mode are reduced from above 5.1% to lower than 2.7% with the proposed control strategy under nonlinear load conditions. The current THD is also reduced from above 21% to lower than 2.4% in the connection point of the microgrid with the offered control scheme in the grid-connected mode. © 2019 ISA 2020-02-03T03:26:50Z 2020-02-03T03:26:50Z 2019 Article 10.1016/j.isatra.2019.04.025 en
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
description This paper proposes an improved hierarchical control strategy consists of a primary and a secondary layer for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions. The primary layer is comprised of a multi-loop control strategy to provide balanced output voltages, a harmonic compensator to reduce the total harmonic distortion (THD), and a droop-based scheme to achieve an accurate power sharing. At the secondary control layer, a reactive power compensator and a frequency restoration loop are designed to improve the accuracy of reactive power sharing and to restore the frequency deviation, respectively. Simulation studies and practical performance are carried out using the DIgSILENT Power Factory software and laboratory testing, to verify the effectiveness of the control strategy in both islanded and grid-connected mode. Zero reactive power sharing error and zero frequency steady-state error have given this control strategy an edge over the conventional control scheme. Furthermore, the proposed scheme presented outstanding voltage control performance, such as fast transient response and low voltage THD. The superiority of the proposed control strategy over the conventional filter-based control scheme is confirmed by the 2 line cycles decrease in the transient response. Additionally, the voltage THDs in islanded mode are reduced from above 5.1% to lower than 2.7% with the proposed control strategy under nonlinear load conditions. The current THD is also reduced from above 21% to lower than 2.4% in the connection point of the microgrid with the offered control scheme in the grid-connected mode. © 2019 ISA
format Article
author Naderipour, A.
Abdul-Malek, Z.
Ramachandaramurthy, V.K.
Kalam, A.
Miveh, M.R.
spellingShingle Naderipour, A.
Abdul-Malek, Z.
Ramachandaramurthy, V.K.
Kalam, A.
Miveh, M.R.
Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions
author_facet Naderipour, A.
Abdul-Malek, Z.
Ramachandaramurthy, V.K.
Kalam, A.
Miveh, M.R.
author_sort Naderipour, A.
title Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions
title_short Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions
title_full Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions
title_fullStr Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions
title_full_unstemmed Hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions
title_sort hierarchical control strategy for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions
publishDate 2020
_version_ 1672614176134004736
score 13.222552