Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section

Connections on the cold-formed steel (CFS) section become an interesting topic concerning its failure mode that the thin-walled behaviour controls it. CFS weakness is usually caused by early local buckling and local instability. The bolt connections and t he gusset plate are the easy way to install...

Full description

Saved in:
Bibliographic Details
Main Authors: Firdaus, M., Saggaff, A., Tahir, M.M., Ngian, S.P., Aminuddin, K.M., Usman, F., Saloma
Format: Article
Language:English
Published: 2020
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-12761
record_format dspace
spelling my.uniten.dspace-127612020-02-03T07:06:53Z Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section Firdaus, M. Saggaff, A. Tahir, M.M. Ngian, S.P. Aminuddin, K.M. Usman, F. Saloma Connections on the cold-formed steel (CFS) section become an interesting topic concerning its failure mode that the thin-walled behaviour controls it. CFS weakness is usually caused by early local buckling and local instability. The bolt connections and t he gusset plate are the easy way to install a joint of steel structures on CFS application. This study is aimed to investigate the behaviour of the CFS connection of double lipped channel C-sections of C20019 for the beam and C30024 for the back-to-back column with a slip-in haunched gusset plate. The haunched gusset plate is S275 steel grade, 6 mm thickness connected with M12 bolt. The experiment was carried out by isolated joint test to acquire moment capacity and rotation of the connection. It is observed that the connection failure modes were on the beam bolt and the local buckling on the column flange. The existence of the slip-in gusset plate reduces the buckling effect induced by the behaviour of the thin plate. The moment of joint (Mj) obtained from the experiment was 20 kNm, the stiffness (Sj) was 250 kNm/rad, and the rotation at the final load was 0.079 radian. The comparison moment of joint by analytical and experimental was 0.78, while the ratio of stiffness was 2.04. The analytical and experi mental comparison between moment of joint and moment resistance of beam was 0.55. It concluded that the connection was categorized as partial strength and ductile connection for cold-formed steel section application. © IJSTR 2019. 2020-02-03T03:26:34Z 2020-02-03T03:26:34Z 2019 Article en
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
description Connections on the cold-formed steel (CFS) section become an interesting topic concerning its failure mode that the thin-walled behaviour controls it. CFS weakness is usually caused by early local buckling and local instability. The bolt connections and t he gusset plate are the easy way to install a joint of steel structures on CFS application. This study is aimed to investigate the behaviour of the CFS connection of double lipped channel C-sections of C20019 for the beam and C30024 for the back-to-back column with a slip-in haunched gusset plate. The haunched gusset plate is S275 steel grade, 6 mm thickness connected with M12 bolt. The experiment was carried out by isolated joint test to acquire moment capacity and rotation of the connection. It is observed that the connection failure modes were on the beam bolt and the local buckling on the column flange. The existence of the slip-in gusset plate reduces the buckling effect induced by the behaviour of the thin plate. The moment of joint (Mj) obtained from the experiment was 20 kNm, the stiffness (Sj) was 250 kNm/rad, and the rotation at the final load was 0.079 radian. The comparison moment of joint by analytical and experimental was 0.78, while the ratio of stiffness was 2.04. The analytical and experi mental comparison between moment of joint and moment resistance of beam was 0.55. It concluded that the connection was categorized as partial strength and ductile connection for cold-formed steel section application. © IJSTR 2019.
format Article
author Firdaus, M.
Saggaff, A.
Tahir, M.M.
Ngian, S.P.
Aminuddin, K.M.
Usman, F.
Saloma
spellingShingle Firdaus, M.
Saggaff, A.
Tahir, M.M.
Ngian, S.P.
Aminuddin, K.M.
Usman, F.
Saloma
Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section
author_facet Firdaus, M.
Saggaff, A.
Tahir, M.M.
Ngian, S.P.
Aminuddin, K.M.
Usman, F.
Saloma
author_sort Firdaus, M.
title Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section
title_short Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section
title_full Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section
title_fullStr Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section
title_full_unstemmed Experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section
title_sort experimental study of slip-in haunched gusset plate connection for double lipped cold-formed steel section
publishDate 2020
_version_ 1662758766032977920
score 13.214268