Value engineering study on drainage design in slope
This study evaluate the value of horizontal drain in slope using value engineering process. The main focus in this study is to achieve the high value of horizontal drain in slope. The usage of horizontal drain is one of the methods that used to lower the high ground water table and hence stabiliz...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
Universiti Malaysia Sarawak, (UNIMAS)
2014
|
Subjects: | |
Online Access: | http://ir.unimas.my/id/eprint/9103/1/Jude.pdf http://ir.unimas.my/id/eprint/9103/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimas.ir.9103 |
---|---|
record_format |
eprints |
spelling |
my.unimas.ir.91032023-08-24T06:45:12Z http://ir.unimas.my/id/eprint/9103/ Value engineering study on drainage design in slope Ting, Jude Mui Heng GE Environmental Sciences This study evaluate the value of horizontal drain in slope using value engineering process. The main focus in this study is to achieve the high value of horizontal drain in slope. The usage of horizontal drain is one of the methods that used to lower the high ground water table and hence stabilize the slope. Several elements in the slope is evaluate and the horizontal drain in the slope is studied on its value. The value of the installation of horizontal drain are investigates through sets of different types of pipes. Others components in slope such as degree of slope, drainage filter and vegetations are studied as well. The combination of different components in the slope is analyzed. Total proposed of 48 alternative design using different combination are studied with their value. From the evaluations obtained from the research, it can be concluded that the pipe that being used in the initial design which is 75mm "Class D" UPVC can be replaced by HDPE Grade PN 10 which will increase the value as much as 13.42%. However, the recommendation is given to the combination of the alternative design which give the increase value as much as 15.77 % by replacement of slope degree from 25o to 35o and 75mm "Class D" UPVC to HDPE Grade PN 10. This study also found that with the increase of slope from 25o to 35o will cost 35.32 %more on vegetation which will only increase the value by 1.85%. Universiti Malaysia Sarawak, (UNIMAS) 2014 Thesis NonPeerReviewed text en http://ir.unimas.my/id/eprint/9103/1/Jude.pdf Ting, Jude Mui Heng (2014) Value engineering study on drainage design in slope. Masters thesis, Universiti Malaysia Sarawak, (UNIMAS). |
institution |
Universiti Malaysia Sarawak |
building |
Centre for Academic Information Services (CAIS) |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sarawak |
content_source |
UNIMAS Institutional Repository |
url_provider |
http://ir.unimas.my/ |
language |
English |
topic |
GE Environmental Sciences |
spellingShingle |
GE Environmental Sciences Ting, Jude Mui Heng Value engineering study on drainage design in slope |
description |
This study evaluate the value of horizontal drain in slope using value
engineering process. The main focus in this study is to achieve the high value of
horizontal drain in slope. The usage of horizontal drain is one of the methods that
used to lower the high ground water table and hence stabilize the slope. Several
elements in the slope is evaluate and the horizontal drain in the slope is studied
on its value. The value of the installation of horizontal drain are investigates
through sets of different types of pipes.
Others components in slope such as degree of slope, drainage filter and
vegetations are studied as well. The combination of different components in the
slope is analyzed. Total proposed of 48 alternative design using different
combination are studied with their value.
From the evaluations obtained from the research, it can be concluded that the
pipe that being used in the initial design which is 75mm "Class D" UPVC can be
replaced by HDPE Grade PN 10 which will increase the value as much as
13.42%. However, the recommendation is given to the combination of the
alternative design which give the increase value as much as 15.77 % by
replacement of slope degree from 25o to 35o and 75mm "Class D" UPVC to
HDPE Grade PN 10. This study also found that with the increase of slope from
25o to 35o will cost 35.32 %more on vegetation which will only increase the
value by 1.85%. |
format |
Thesis |
author |
Ting, Jude Mui Heng |
author_facet |
Ting, Jude Mui Heng |
author_sort |
Ting, Jude Mui Heng |
title |
Value engineering study on drainage design in slope |
title_short |
Value engineering study on drainage design in slope |
title_full |
Value engineering study on drainage design in slope |
title_fullStr |
Value engineering study on drainage design in slope |
title_full_unstemmed |
Value engineering study on drainage design in slope |
title_sort |
value engineering study on drainage design in slope |
publisher |
Universiti Malaysia Sarawak, (UNIMAS) |
publishDate |
2014 |
url |
http://ir.unimas.my/id/eprint/9103/1/Jude.pdf http://ir.unimas.my/id/eprint/9103/ |
_version_ |
1775627186145853440 |
score |
13.188404 |