Indoor Air Quality in UNIMAS Detar Putra Convocation Hall

This study was conducted to determine the comfort conditions and Indoor Air Quality during convocation in UNIMAS convocation hall, Sarawak Malaysia with the capacity of 5000 occupants. Heating, ventilating and air conditioning (HVAC) systems of the hall should be design to serve and providing good i...

Full description

Saved in:
Bibliographic Details
Main Authors: Christopher J., Boniface, Mohammad Shahril, B. Osman, Syed Tarmizi, Syed Shazalic
Format: E-Article
Published: ENCON 2013 2013
Subjects:
Online Access:http://ir.unimas.my/id/eprint/8164/
http://rpsonline.com.sg/proceedings/9789810760595/html/021.xml
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.8164
record_format eprints
spelling my.unimas.ir.81642015-07-02T06:25:04Z http://ir.unimas.my/id/eprint/8164/ Indoor Air Quality in UNIMAS Detar Putra Convocation Hall Christopher J., Boniface Mohammad Shahril, B. Osman Syed Tarmizi, Syed Shazalic Q Science (General) This study was conducted to determine the comfort conditions and Indoor Air Quality during convocation in UNIMAS convocation hall, Sarawak Malaysia with the capacity of 5000 occupants. Heating, ventilating and air conditioning (HVAC) systems of the hall should be design to serve and providing good indoor air quality. For the investigations, all of the IAQ monitoring equipments used in this study were supplied and assisted from Department Of Occupational Safety and Health (DOSH) Ministry of Human Resources Malaysia. Monitoring equipments were used to obtain the IAQ data parameters were based on Industry Code Of Practice On Indoor Air Quality 2010 DOSH Malaysia. In this study, maximum and minimum air movement for convocation hall are 0.05 m/s and 0.09 m/s respectively below range and humidity of above 70% as specified by DOSH Malaysia. Approximately at 2500 occupant, carbon dioxide concentrations are between minimum 834 ppm and 890 ppm maximum. With these figures are indications of inadequate ventilation on UNIMAS Detar Putra Convocation hall. ENCON 2013 2013 E-Article PeerReviewed Christopher J., Boniface and Mohammad Shahril, B. Osman and Syed Tarmizi, Syed Shazalic (2013) Indoor Air Quality in UNIMAS Detar Putra Convocation Hall. ENCON 2013. http://rpsonline.com.sg/proceedings/9789810760595/html/021.xml doi: 10.3850/978-981-07-6059-5_021
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
topic Q Science (General)
spellingShingle Q Science (General)
Christopher J., Boniface
Mohammad Shahril, B. Osman
Syed Tarmizi, Syed Shazalic
Indoor Air Quality in UNIMAS Detar Putra Convocation Hall
description This study was conducted to determine the comfort conditions and Indoor Air Quality during convocation in UNIMAS convocation hall, Sarawak Malaysia with the capacity of 5000 occupants. Heating, ventilating and air conditioning (HVAC) systems of the hall should be design to serve and providing good indoor air quality. For the investigations, all of the IAQ monitoring equipments used in this study were supplied and assisted from Department Of Occupational Safety and Health (DOSH) Ministry of Human Resources Malaysia. Monitoring equipments were used to obtain the IAQ data parameters were based on Industry Code Of Practice On Indoor Air Quality 2010 DOSH Malaysia. In this study, maximum and minimum air movement for convocation hall are 0.05 m/s and 0.09 m/s respectively below range and humidity of above 70% as specified by DOSH Malaysia. Approximately at 2500 occupant, carbon dioxide concentrations are between minimum 834 ppm and 890 ppm maximum. With these figures are indications of inadequate ventilation on UNIMAS Detar Putra Convocation hall.
format E-Article
author Christopher J., Boniface
Mohammad Shahril, B. Osman
Syed Tarmizi, Syed Shazalic
author_facet Christopher J., Boniface
Mohammad Shahril, B. Osman
Syed Tarmizi, Syed Shazalic
author_sort Christopher J., Boniface
title Indoor Air Quality in UNIMAS Detar Putra Convocation Hall
title_short Indoor Air Quality in UNIMAS Detar Putra Convocation Hall
title_full Indoor Air Quality in UNIMAS Detar Putra Convocation Hall
title_fullStr Indoor Air Quality in UNIMAS Detar Putra Convocation Hall
title_full_unstemmed Indoor Air Quality in UNIMAS Detar Putra Convocation Hall
title_sort indoor air quality in unimas detar putra convocation hall
publisher ENCON 2013
publishDate 2013
url http://ir.unimas.my/id/eprint/8164/
http://rpsonline.com.sg/proceedings/9789810760595/html/021.xml
_version_ 1644510471432175616
score 13.214268