Electrical energy price has been increa sing over the years. Due to this reason, home users are getting more concern about the efficiency of the electrical appliances . The solution on this problem is to create an energy usage monitoring system that can mon...

Full description

Saved in:
Bibliographic Details
Main Author: Chong, Kian Tat
Format: Final Year Project Report
Language:English
English
Published: Universiti Malaysia Sarawak, UNIMAS 2009
Subjects:
Online Access:http://ir.unimas.my/id/eprint/6514/1/ENERGY%20USAGE%20MONITORING%20SYSTEM%2824%20pgs%29.pdf
http://ir.unimas.my/id/eprint/6514/8/ENERGY%20USAGE%20MONITORING%20SYSTEM%28OCR%29.pdf
http://ir.unimas.my/id/eprint/6514/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.6514
record_format eprints
spelling my.unimas.ir.65142023-02-08T02:28:55Z http://ir.unimas.my/id/eprint/6514/ Energy usage monitoring system Chong, Kian Tat T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Electrical energy price has been increa sing over the years. Due to this reason, home users are getting more concern about the efficiency of the electrical appliances . The solution on this problem is to create an energy usage monitoring system that can monitor the energy used by electrical appliances . The objective of this project is to design and build a computer based energy monitoring system. The system will be consisting of a compu ter, a data acquisition (DAQ) module , a voltage sensor and a current sensor. The LabVIEW graphical programming software by National Instrument Inc. is used to design and build the computer interfacing software (virtual instrument software) . Th e system is a ble to measure the source frequency, source voltage, current drown by the monitored device, real power, apparent power, power factor, phase shift between the voltage graph and the current graph (in both radiance and degree), kilo - Watt - hour reading, monito red device operation time (elapsed time) and cost of operation of the monitored device. The measured data is presented in both graphical and numerical form. The system also has error detection capability (over voltage, voltage too low and over current dete ction) which will cut off the power supply when error is detected. The database of the system is able to store both measurement data and error report. This system can be accessed remotely by using the Windows Remote Desktop Connection software. Universiti Malaysia Sarawak, UNIMAS 2009 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/6514/1/ENERGY%20USAGE%20MONITORING%20SYSTEM%2824%20pgs%29.pdf text en http://ir.unimas.my/id/eprint/6514/8/ENERGY%20USAGE%20MONITORING%20SYSTEM%28OCR%29.pdf Chong, Kian Tat (2009) Energy usage monitoring system. [Final Year Project Report] (Unpublished)
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
English
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Chong, Kian Tat
Energy usage monitoring system
description Electrical energy price has been increa sing over the years. Due to this reason, home users are getting more concern about the efficiency of the electrical appliances . The solution on this problem is to create an energy usage monitoring system that can monitor the energy used by electrical appliances . The objective of this project is to design and build a computer based energy monitoring system. The system will be consisting of a compu ter, a data acquisition (DAQ) module , a voltage sensor and a current sensor. The LabVIEW graphical programming software by National Instrument Inc. is used to design and build the computer interfacing software (virtual instrument software) . Th e system is a ble to measure the source frequency, source voltage, current drown by the monitored device, real power, apparent power, power factor, phase shift between the voltage graph and the current graph (in both radiance and degree), kilo - Watt - hour reading, monito red device operation time (elapsed time) and cost of operation of the monitored device. The measured data is presented in both graphical and numerical form. The system also has error detection capability (over voltage, voltage too low and over current dete ction) which will cut off the power supply when error is detected. The database of the system is able to store both measurement data and error report. This system can be accessed remotely by using the Windows Remote Desktop Connection software.
format Final Year Project Report
author Chong, Kian Tat
author_facet Chong, Kian Tat
author_sort Chong, Kian Tat
title Energy usage monitoring system
title_short Energy usage monitoring system
title_full Energy usage monitoring system
title_fullStr Energy usage monitoring system
title_full_unstemmed Energy usage monitoring system
title_sort energy usage monitoring system
publisher Universiti Malaysia Sarawak, UNIMAS
publishDate 2009
url http://ir.unimas.my/id/eprint/6514/1/ENERGY%20USAGE%20MONITORING%20SYSTEM%2824%20pgs%29.pdf