The objective of this experiment is to develop a heat exchanger system that used the biomass decomposition process heat as the source of energy. The system will be design and construct based on the operating principles of geothermal heat pumps and the feasibility and flexibility of the system will...

Full description

Saved in:
Bibliographic Details
Main Author: Han, N.T.H
Format: Final Year Project Report
Language:English
English
Published: Universiti Malaysia Sarawak, UNIMAS 2010
Subjects:
Online Access:http://ir.unimas.my/id/eprint/4599/1/Waste%20Thermal%20Heat%20Pump%20%2824pgs%29.pdf
http://ir.unimas.my/id/eprint/4599/7/Nicholas%20HTH.pdf
http://ir.unimas.my/id/eprint/4599/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.4599
record_format eprints
spelling my.unimas.ir.45992023-11-14T06:48:00Z http://ir.unimas.my/id/eprint/4599/ Waste thermal heat pump Han, N.T.H TA Engineering (General). Civil engineering (General) The objective of this experiment is to develop a heat exchanger system that used the biomass decomposition process heat as the source of energy. The system will be design and construct based on the operating principles of geothermal heat pumps and the feasibility and flexibility of the system will be analyzed. The design is comprised of a heat exchanger coil that is placed at the bottom of the container with water circulates through the coil to extract heat from the decomposition process. The proposed system will be compared to a control system, a system without heat exchanger coil to see the effect of heat exchanger coil on the biomass temperature and also its decomposition rate. This experiment also introduced the double stage heating system to increase the temperature difference of the water between the inlet and outlet of the system. The moisture content of the grass in the first cycle is 71.5% and 74.8% for the second cycle. The average power output per kg dry matter produced from the double stage heating for the first and second cycle is 0.41 Watt/kg and 0.47 Watt/kg Universiti Malaysia Sarawak, UNIMAS 2010 Final Year Project Report NonPeerReviewed text en http://ir.unimas.my/id/eprint/4599/1/Waste%20Thermal%20Heat%20Pump%20%2824pgs%29.pdf text en http://ir.unimas.my/id/eprint/4599/7/Nicholas%20HTH.pdf Han, N.T.H (2010) Waste thermal heat pump. [Final Year Project Report] (Unpublished)
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Han, N.T.H
Waste thermal heat pump
description The objective of this experiment is to develop a heat exchanger system that used the biomass decomposition process heat as the source of energy. The system will be design and construct based on the operating principles of geothermal heat pumps and the feasibility and flexibility of the system will be analyzed. The design is comprised of a heat exchanger coil that is placed at the bottom of the container with water circulates through the coil to extract heat from the decomposition process. The proposed system will be compared to a control system, a system without heat exchanger coil to see the effect of heat exchanger coil on the biomass temperature and also its decomposition rate. This experiment also introduced the double stage heating system to increase the temperature difference of the water between the inlet and outlet of the system. The moisture content of the grass in the first cycle is 71.5% and 74.8% for the second cycle. The average power output per kg dry matter produced from the double stage heating for the first and second cycle is 0.41 Watt/kg and 0.47 Watt/kg
format Final Year Project Report
author Han, N.T.H
author_facet Han, N.T.H
author_sort Han, N.T.H
title Waste thermal heat pump
title_short Waste thermal heat pump
title_full Waste thermal heat pump
title_fullStr Waste thermal heat pump
title_full_unstemmed Waste thermal heat pump
title_sort waste thermal heat pump
publisher Universiti Malaysia Sarawak, UNIMAS
publishDate 2010
url http://ir.unimas.my/id/eprint/4599/1/Waste%20Thermal%20Heat%20Pump%20%2824pgs%29.pdf
http://ir.unimas.my/id/eprint/4599/7/Nicholas%20HTH.pdf
http://ir.unimas.my/id/eprint/4599/
_version_ 1783883448992137216
score 13.160551