Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods

Simultaneous determination of dissolved silver (dAg) with other key GEOTRACES trace metals is difficult because dAg in seawater tends to form negatively charged chloride species that result in only 75% recovery efficiency with commonly used NOBIAS PA-1 chelating resins. In this study, we developed a...

Full description

Saved in:
Bibliographic Details
Main Authors: Wong, Kuo Hong, Keisuke, Nishitani, Hajime, Obata, Hideki, Fukuda, Hiroshi, Ogawa, Farah Akmal, Idrus, Fatimah A'tirah, Mohamad, Asami S., Mashio, Hiroshi, Hasegawa
Format: Article
Language:English
Published: Elsevier B.V. 2024
Subjects:
Online Access:http://ir.unimas.my/id/eprint/44737/1/Simultaneous%20determination.pdf
http://ir.unimas.my/id/eprint/44737/
https://www.sciencedirect.com/science/article/pii/S0304420324000471?via%3Dihub
https://doi.org/10.1016/j.marchem.2024.104396
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.44737
record_format eprints
spelling my.unimas.ir.447372024-05-13T03:55:34Z http://ir.unimas.my/id/eprint/44737/ Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods Wong, Kuo Hong Keisuke, Nishitani Hajime, Obata Hideki, Fukuda Hiroshi, Ogawa Farah Akmal, Idrus Fatimah A'tirah, Mohamad Asami S., Mashio Hiroshi, Hasegawa GC Oceanography GE Environmental Sciences Simultaneous determination of dissolved silver (dAg) with other key GEOTRACES trace metals is difficult because dAg in seawater tends to form negatively charged chloride species that result in only 75% recovery efficiency with commonly used NOBIAS PA-1 chelating resins. In this study, we developed a method using solid phase extraction coupled with isotope dilution that enables full quantification (97.9 ± 2.1%) of dAg along with other major trace metals including cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), and lead (Pb) (recovery efficiency = 100% to 102%) in seawater samples. Seawater samples were first spiked with Ag-109 and allowed to reach isotopic equilibrium before extraction using NOBIAS PA-1 chelating resin. Then, dAg isotope ratios (Ag-109/Ag-107) before and after solid phase extraction were determined and used to quantify dAg. Determination of dAg with dissolved Cd, Cu. Mn, Ni, and Pb in reference seawater material CASS-6 resulted in deviations of between 1.0% and 8.8% from the consensus values, which are well within the standard error of measurement. We then successfully determined the concentrations of dissolved Cd (0.05–0.2 nM), Cu (0.5–13 nM), Mn (10–140 nM), Ni (2–12 nM), Pb (5–110 nM), and Ag (10–40 pM) in Otsuchi Bay, Japan and its surrounding rivers. Evaluation of the behavior of dAg under a salinity gradient using estuarine samples collected from Samunsam River, Malaysia shows increasing dAg concentration with salinity (R2 = 0.68), which suggests release of sedimental Ag under high ambient chloride concentrations. Our new method enables rapid and simultaneous measurements of dAg with other key GEOTRACES trace metals in a sin. Elsevier B.V. 2024 Article PeerReviewed text en http://ir.unimas.my/id/eprint/44737/1/Simultaneous%20determination.pdf Wong, Kuo Hong and Keisuke, Nishitani and Hajime, Obata and Hideki, Fukuda and Hiroshi, Ogawa and Farah Akmal, Idrus and Fatimah A'tirah, Mohamad and Asami S., Mashio and Hiroshi, Hasegawa (2024) Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods. Marine Chemistry, 262. pp. 1-7. ISSN 0304-4203 https://www.sciencedirect.com/science/article/pii/S0304420324000471?via%3Dihub https://doi.org/10.1016/j.marchem.2024.104396
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic GC Oceanography
GE Environmental Sciences
spellingShingle GC Oceanography
GE Environmental Sciences
Wong, Kuo Hong
Keisuke, Nishitani
Hajime, Obata
Hideki, Fukuda
Hiroshi, Ogawa
Farah Akmal, Idrus
Fatimah A'tirah, Mohamad
Asami S., Mashio
Hiroshi, Hasegawa
Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods
description Simultaneous determination of dissolved silver (dAg) with other key GEOTRACES trace metals is difficult because dAg in seawater tends to form negatively charged chloride species that result in only 75% recovery efficiency with commonly used NOBIAS PA-1 chelating resins. In this study, we developed a method using solid phase extraction coupled with isotope dilution that enables full quantification (97.9 ± 2.1%) of dAg along with other major trace metals including cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), and lead (Pb) (recovery efficiency = 100% to 102%) in seawater samples. Seawater samples were first spiked with Ag-109 and allowed to reach isotopic equilibrium before extraction using NOBIAS PA-1 chelating resin. Then, dAg isotope ratios (Ag-109/Ag-107) before and after solid phase extraction were determined and used to quantify dAg. Determination of dAg with dissolved Cd, Cu. Mn, Ni, and Pb in reference seawater material CASS-6 resulted in deviations of between 1.0% and 8.8% from the consensus values, which are well within the standard error of measurement. We then successfully determined the concentrations of dissolved Cd (0.05–0.2 nM), Cu (0.5–13 nM), Mn (10–140 nM), Ni (2–12 nM), Pb (5–110 nM), and Ag (10–40 pM) in Otsuchi Bay, Japan and its surrounding rivers. Evaluation of the behavior of dAg under a salinity gradient using estuarine samples collected from Samunsam River, Malaysia shows increasing dAg concentration with salinity (R2 = 0.68), which suggests release of sedimental Ag under high ambient chloride concentrations. Our new method enables rapid and simultaneous measurements of dAg with other key GEOTRACES trace metals in a sin.
format Article
author Wong, Kuo Hong
Keisuke, Nishitani
Hajime, Obata
Hideki, Fukuda
Hiroshi, Ogawa
Farah Akmal, Idrus
Fatimah A'tirah, Mohamad
Asami S., Mashio
Hiroshi, Hasegawa
author_facet Wong, Kuo Hong
Keisuke, Nishitani
Hajime, Obata
Hideki, Fukuda
Hiroshi, Ogawa
Farah Akmal, Idrus
Fatimah A'tirah, Mohamad
Asami S., Mashio
Hiroshi, Hasegawa
author_sort Wong, Kuo Hong
title Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods
title_short Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods
title_full Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods
title_fullStr Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods
title_full_unstemmed Simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods
title_sort simultaneous determination of picomolar level of dissolved silver with other key trace metals in seawater samples using solid phase extraction and isotope dilution methods
publisher Elsevier B.V.
publishDate 2024
url http://ir.unimas.my/id/eprint/44737/1/Simultaneous%20determination.pdf
http://ir.unimas.my/id/eprint/44737/
https://www.sciencedirect.com/science/article/pii/S0304420324000471?via%3Dihub
https://doi.org/10.1016/j.marchem.2024.104396
_version_ 1800728083995557888
score 13.18916