A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme

This paper aims to assess the performance of a centralized single-stage grid-tied three-level diode clamped inverter connected to a PVFuel cell unit. An active and reactive power open-loop control scheme is employed to operate the inverter and achieves a current harmonic distortion below 5%. The sys...

Full description

Saved in:
Bibliographic Details
Main Authors: Magdi G., Muftah, Mohamed, Salem, Yonis M Yonis, Buswig, Khlid Ben, Hamid, Doudou N., Louta, Mohamad, Kamarol
Format: Article
Language:English
Published: Frontiers 2022
Subjects:
Online Access:http://ir.unimas.my/id/eprint/40871/3/A%20grid-tied%20PV-fuel%20cell%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/40871/
https://www.frontiersin.org/journals/energy-research
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.40871
record_format eprints
spelling my.unimas.ir.408712022-12-16T03:27:39Z http://ir.unimas.my/id/eprint/40871/ A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme Magdi G., Muftah Mohamed, Salem Yonis M Yonis, Buswig Khlid Ben, Hamid Doudou N., Louta Mohamad, Kamarol TK Electrical engineering. Electronics Nuclear engineering This paper aims to assess the performance of a centralized single-stage grid-tied three-level diode clamped inverter connected to a PVFuel cell unit. An active and reactive power open-loop control scheme is employed to operate the inverter and achieves a current harmonic distortion below 5%. The system comprises a 150 kW/700 V PV, a 150 kW/1400 V fuel cell, a 265 kW multilevel inverter operating at a rated voltage of 415 V, and an LCL filter. Two operating scenarios are adopted to investigate the system’s responses further. In the first scenario, a local load of 509.2 kW is supplied from the PV-fuel cell inverter. The load also receives the grid’s power to meet the demand as the PV-fuel cell inverter provides only 265 kW. Whereas in the other scenario, the PV-fuel cell unit provides power to supply a local load while transporting the surplus to the grid. The results reveal the developed model’s good performance with a current harmonic distortion of 0.33%. Frontiers 2022-12-08 Article PeerReviewed text en http://ir.unimas.my/id/eprint/40871/3/A%20grid-tied%20PV-fuel%20cell%20-%20Copy.pdf Magdi G., Muftah and Mohamed, Salem and Yonis M Yonis, Buswig and Khlid Ben, Hamid and Doudou N., Louta and Mohamad, Kamarol (2022) A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme. Frontiers in Energy Research, 10 (3389). pp. 1-17. ISSN 2296-598X https://www.frontiersin.org/journals/energy-research doi: 10.3389/fenrg.2022.968371
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Magdi G., Muftah
Mohamed, Salem
Yonis M Yonis, Buswig
Khlid Ben, Hamid
Doudou N., Louta
Mohamad, Kamarol
A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme
description This paper aims to assess the performance of a centralized single-stage grid-tied three-level diode clamped inverter connected to a PVFuel cell unit. An active and reactive power open-loop control scheme is employed to operate the inverter and achieves a current harmonic distortion below 5%. The system comprises a 150 kW/700 V PV, a 150 kW/1400 V fuel cell, a 265 kW multilevel inverter operating at a rated voltage of 415 V, and an LCL filter. Two operating scenarios are adopted to investigate the system’s responses further. In the first scenario, a local load of 509.2 kW is supplied from the PV-fuel cell inverter. The load also receives the grid’s power to meet the demand as the PV-fuel cell inverter provides only 265 kW. Whereas in the other scenario, the PV-fuel cell unit provides power to supply a local load while transporting the surplus to the grid. The results reveal the developed model’s good performance with a current harmonic distortion of 0.33%.
format Article
author Magdi G., Muftah
Mohamed, Salem
Yonis M Yonis, Buswig
Khlid Ben, Hamid
Doudou N., Louta
Mohamad, Kamarol
author_facet Magdi G., Muftah
Mohamed, Salem
Yonis M Yonis, Buswig
Khlid Ben, Hamid
Doudou N., Louta
Mohamad, Kamarol
author_sort Magdi G., Muftah
title A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme
title_short A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme
title_full A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme
title_fullStr A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme
title_full_unstemmed A grid-tied PV-fuel cell multilevel inverter under PQ open-loop control scheme
title_sort grid-tied pv-fuel cell multilevel inverter under pq open-loop control scheme
publisher Frontiers
publishDate 2022
url http://ir.unimas.my/id/eprint/40871/3/A%20grid-tied%20PV-fuel%20cell%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/40871/
https://www.frontiersin.org/journals/energy-research
_version_ 1753792653355384832