Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels

To date, microfluidic device has contributed significantly in biotechnology and life sciences due to their fast response time, low consumption of samples and high sensitivity. Although it is widely utilized in bio-, nano-, and environmental technologies, there are still limited experimental investig...

Full description

Saved in:
Bibliographic Details
Main Author: Hawa, Ringkai
Format: Thesis
Language:English
Published: Universiti Malaysia Sarawak 2022
Subjects:
Online Access:http://ir.unimas.my/id/eprint/39190/1/Hawa.pdf
http://ir.unimas.my/id/eprint/39190/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.39190
record_format eprints
spelling my.unimas.ir.391902023-04-12T00:31:25Z http://ir.unimas.my/id/eprint/39190/ Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels Hawa, Ringkai TJ Mechanical engineering and machinery To date, microfluidic device has contributed significantly in biotechnology and life sciences due to their fast response time, low consumption of samples and high sensitivity. Although it is widely utilized in bio-, nano-, and environmental technologies, there are still limited experimental investigations on the micromixing process of dissimilar liquids i.e., in cosmetics, construction and biofuel production. In this study, the mixing index of propan-2-ol and water, water and sodium chloride solution, propan-2-ol and sodium chloride solution were characterized and reported at 5 ≤ Re ≤ 50 inside the 750 μm-radius of fabricated T-junction and offset T-junction microfluidic channel. By using RGB colour model method, both microchannels for miscible mixing experiments show better mixing index at high Reynolds number (Re) of 40 and 50 due to the significant convection which is caused by the effect of stretching and thinning of liquid lamellae. Meanwhile, for immiscible mixture, offset T-junction yielded superior mixing performance than T-junction microchannel at both low and high Re. Hence, due to the fact that offset T-junction performs better than T-junction, the study was furthered by investigating the behaviours of water-in-oil droplet at interfacial surface within offset T-junction microchannel having different size i.e., radius of 400 μm, 500 μm, 750 μm and 1000 μm using micro-PIV software. The results showed that experimental velocity of the water droplet holds good agreement with theoretical values, having minimal difference as low as 0.004 mm/s for the case of microchannel with radius 750 μm. A maintained average velocity of 0.055 mm/s for channel with radius of 1000 μm was achieved, meanwhile the other channels showed a good average velocity data i.e., an increase from 0.15 mm/s to 0.20 mm/s for channel radius of 500 μm. In addition, a major elevation for mean velocity from 0.055 mm/s to 0.15 mm/s for channel with radius of 750 μm was also seen. The proposed design of microfluidic device especially offset T-junction offers more efficient and better results in micromixing study of immiscible liquids. Universiti Malaysia Sarawak 2022-08-13 Thesis NonPeerReviewed text en http://ir.unimas.my/id/eprint/39190/1/Hawa.pdf Hawa, Ringkai (2022) Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels. Masters thesis, Universiti Malaysia Sarawak.
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Hawa, Ringkai
Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels
description To date, microfluidic device has contributed significantly in biotechnology and life sciences due to their fast response time, low consumption of samples and high sensitivity. Although it is widely utilized in bio-, nano-, and environmental technologies, there are still limited experimental investigations on the micromixing process of dissimilar liquids i.e., in cosmetics, construction and biofuel production. In this study, the mixing index of propan-2-ol and water, water and sodium chloride solution, propan-2-ol and sodium chloride solution were characterized and reported at 5 ≤ Re ≤ 50 inside the 750 μm-radius of fabricated T-junction and offset T-junction microfluidic channel. By using RGB colour model method, both microchannels for miscible mixing experiments show better mixing index at high Reynolds number (Re) of 40 and 50 due to the significant convection which is caused by the effect of stretching and thinning of liquid lamellae. Meanwhile, for immiscible mixture, offset T-junction yielded superior mixing performance than T-junction microchannel at both low and high Re. Hence, due to the fact that offset T-junction performs better than T-junction, the study was furthered by investigating the behaviours of water-in-oil droplet at interfacial surface within offset T-junction microchannel having different size i.e., radius of 400 μm, 500 μm, 750 μm and 1000 μm using micro-PIV software. The results showed that experimental velocity of the water droplet holds good agreement with theoretical values, having minimal difference as low as 0.004 mm/s for the case of microchannel with radius 750 μm. A maintained average velocity of 0.055 mm/s for channel with radius of 1000 μm was achieved, meanwhile the other channels showed a good average velocity data i.e., an increase from 0.15 mm/s to 0.20 mm/s for channel radius of 500 μm. In addition, a major elevation for mean velocity from 0.055 mm/s to 0.15 mm/s for channel with radius of 750 μm was also seen. The proposed design of microfluidic device especially offset T-junction offers more efficient and better results in micromixing study of immiscible liquids.
format Thesis
author Hawa, Ringkai
author_facet Hawa, Ringkai
author_sort Hawa, Ringkai
title Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels
title_short Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels
title_full Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels
title_fullStr Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels
title_full_unstemmed Investigation on Mixing Performance and Droplet Generation of Dissimilar Liquids through T-junction and Offset T-junction Microchannels
title_sort investigation on mixing performance and droplet generation of dissimilar liquids through t-junction and offset t-junction microchannels
publisher Universiti Malaysia Sarawak
publishDate 2022
url http://ir.unimas.my/id/eprint/39190/1/Hawa.pdf
http://ir.unimas.my/id/eprint/39190/
_version_ 1762965689763627008
score 13.160551