Certified reference materials for analytical quality control in neutron activation analysis

Analytical quality control in neutron activation analysis (NAA) requires the use of certified reference materials (CRM) in order to produce reliable analytical results. It is essential to evaluate the performance of NAA method when analyzing various sample matrices. Therefore, the CRM selected for a...

Full description

Saved in:
Bibliographic Details
Main Authors: Wee, Boon Siong, Abdul Khalik, Wood, Mohd. Suhaimi, Hamzah, Shamsiah, Abdul Rahman, Md. Suhaimi, Elias, Nazaratul Ashifa, Abdullah Salim
Format: Article
Language:English
Published: International Atomic Energy Agency (IAEA) 2007
Subjects:
Online Access:http://ir.unimas.my/id/eprint/31366/1/Certified%20reference%20materials%20for%20analytical%20quality%20control%20in%20neutron%20activation%20analysis%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/31366/
https://inis.iaea.org/search/search.aspx?orig_q=RN:42092313
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.31366
record_format eprints
spelling my.unimas.ir.313662023-08-14T03:13:44Z http://ir.unimas.my/id/eprint/31366/ Certified reference materials for analytical quality control in neutron activation analysis Wee, Boon Siong Abdul Khalik, Wood Mohd. Suhaimi, Hamzah Shamsiah, Abdul Rahman Md. Suhaimi, Elias Nazaratul Ashifa, Abdullah Salim TP Chemical technology Analytical quality control in neutron activation analysis (NAA) requires the use of certified reference materials (CRM) in order to produce reliable analytical results. It is essential to evaluate the performance of NAA method when analyzing various sample matrices. Therefore, the CRM selected for an analysis should be suitable for the type of samples. There are many aspects such as concentration range, matrix match, sample size, and uncertainty, which need to be considered when selecting a suitable CRM. Eventually, results of analysis of CRM were plotted into control charts in order to evaluate the quality of the data. This is to ensure that the results are within the 95% confidence interval as stipulated in the certificate of CRM. Thus, this article aims to discuss the uses of certified reference materials for quality control purposes in NAA involving various sample matrices. International Atomic Energy Agency (IAEA) 2007 Article PeerReviewed text en http://ir.unimas.my/id/eprint/31366/1/Certified%20reference%20materials%20for%20analytical%20quality%20control%20in%20neutron%20activation%20analysis%20-%20Copy.pdf Wee, Boon Siong and Abdul Khalik, Wood and Mohd. Suhaimi, Hamzah and Shamsiah, Abdul Rahman and Md. Suhaimi, Elias and Nazaratul Ashifa, Abdullah Salim (2007) Certified reference materials for analytical quality control in neutron activation analysis. The Malaysian Journal of Analytical Sciences, 11 (1). pp. 17-22. ISSN 1394-2506 https://inis.iaea.org/search/search.aspx?orig_q=RN:42092313
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Wee, Boon Siong
Abdul Khalik, Wood
Mohd. Suhaimi, Hamzah
Shamsiah, Abdul Rahman
Md. Suhaimi, Elias
Nazaratul Ashifa, Abdullah Salim
Certified reference materials for analytical quality control in neutron activation analysis
description Analytical quality control in neutron activation analysis (NAA) requires the use of certified reference materials (CRM) in order to produce reliable analytical results. It is essential to evaluate the performance of NAA method when analyzing various sample matrices. Therefore, the CRM selected for an analysis should be suitable for the type of samples. There are many aspects such as concentration range, matrix match, sample size, and uncertainty, which need to be considered when selecting a suitable CRM. Eventually, results of analysis of CRM were plotted into control charts in order to evaluate the quality of the data. This is to ensure that the results are within the 95% confidence interval as stipulated in the certificate of CRM. Thus, this article aims to discuss the uses of certified reference materials for quality control purposes in NAA involving various sample matrices.
format Article
author Wee, Boon Siong
Abdul Khalik, Wood
Mohd. Suhaimi, Hamzah
Shamsiah, Abdul Rahman
Md. Suhaimi, Elias
Nazaratul Ashifa, Abdullah Salim
author_facet Wee, Boon Siong
Abdul Khalik, Wood
Mohd. Suhaimi, Hamzah
Shamsiah, Abdul Rahman
Md. Suhaimi, Elias
Nazaratul Ashifa, Abdullah Salim
author_sort Wee, Boon Siong
title Certified reference materials for analytical quality control in neutron activation analysis
title_short Certified reference materials for analytical quality control in neutron activation analysis
title_full Certified reference materials for analytical quality control in neutron activation analysis
title_fullStr Certified reference materials for analytical quality control in neutron activation analysis
title_full_unstemmed Certified reference materials for analytical quality control in neutron activation analysis
title_sort certified reference materials for analytical quality control in neutron activation analysis
publisher International Atomic Energy Agency (IAEA)
publishDate 2007
url http://ir.unimas.my/id/eprint/31366/1/Certified%20reference%20materials%20for%20analytical%20quality%20control%20in%20neutron%20activation%20analysis%20-%20Copy.pdf
http://ir.unimas.my/id/eprint/31366/
https://inis.iaea.org/search/search.aspx?orig_q=RN:42092313
_version_ 1775627279227944960
score 13.160551