Development and performance evaluation of A 3-stage treatment system for domestic wastewater

This research project focuses on the development and performance tests of a 3-stage domestic wastewater treatment system which consists of; 1) Spiral-Framed Human Hair-Based Filter (HBF), 2) Biotower (BT), and 3) Pistia Stratiotes-Based Free Water Surface System (FWS) for removal of oil and grease (...

Full description

Saved in:
Bibliographic Details
Main Author: Oon, Yin Wee.
Format: Thesis
Language:English
Published: Universiti Malaysia Sarawak (UNIMAS) 2008
Subjects:
Online Access:http://ir.unimas.my/id/eprint/30294/1/Oon%20Yin%20Wee%20ft.pdf
http://ir.unimas.my/id/eprint/30294/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.30294
record_format eprints
spelling my.unimas.ir.302942023-06-21T03:46:40Z http://ir.unimas.my/id/eprint/30294/ Development and performance evaluation of A 3-stage treatment system for domestic wastewater Oon, Yin Wee. TD Environmental technology. Sanitary engineering This research project focuses on the development and performance tests of a 3-stage domestic wastewater treatment system which consists of; 1) Spiral-Framed Human Hair-Based Filter (HBF), 2) Biotower (BT), and 3) Pistia Stratiotes-Based Free Water Surface System (FWS) for removal of oil and grease (O&G), suspended solids (SS), ammoniacal-nitrogen (NH3-N), biochemical oxygen demand (BODs) and nutrients such as nitrogen (N), phosphorous (P), and potassium(K) prior to discharge to natural waterway; The three primary components of the system operated in series. Domestic wastewaters were first induced to flow in a spiral pattern in the HBF for removal of O&G. The effluents from HBF were then trickled through the BT filled with perforated cylindrical plastic tubes to provide cross-flow alternated with vertical flow for removal ofSS, NH3-N, BODs and N. The final stage of the system was the FWS that focused on the removal of nutrients (N, P, K) by using a type of Sarawak local water lettuce called "Pistia Stratiotes". From this research, it was found that HBF achieved approximately . 73.54% removal of O&G, while the removal rates of BOD, NH3-N, N, P, K and SS by the biotower (TF) were approximately 35.0%, 57.4%, 51.8%, 13.4%, 21.8%, and 21.9%, respectively. The pollutant removal rates achieved by FWS were approximately 24.1 % BOD, 30.6% NH3-N, 38.0% N, 41.5% P, 46.7% K, and 37.1% SS. The overall combined removal efficiencies of HBF, BT and FWS were approximately 73.5%, 59.2%, 87.9%,90.6%, 54.9%, 68.5%, and 59.0% for O&G, BOD, NH3-N, N, P, K and SS, respectively. Universiti Malaysia Sarawak (UNIMAS) 2008 Thesis NonPeerReviewed text en http://ir.unimas.my/id/eprint/30294/1/Oon%20Yin%20Wee%20ft.pdf Oon, Yin Wee. (2008) Development and performance evaluation of A 3-stage treatment system for domestic wastewater. Masters thesis, Universiti Malaysia Sarawak (UNIMAS).
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic TD Environmental technology. Sanitary engineering
spellingShingle TD Environmental technology. Sanitary engineering
Oon, Yin Wee.
Development and performance evaluation of A 3-stage treatment system for domestic wastewater
description This research project focuses on the development and performance tests of a 3-stage domestic wastewater treatment system which consists of; 1) Spiral-Framed Human Hair-Based Filter (HBF), 2) Biotower (BT), and 3) Pistia Stratiotes-Based Free Water Surface System (FWS) for removal of oil and grease (O&G), suspended solids (SS), ammoniacal-nitrogen (NH3-N), biochemical oxygen demand (BODs) and nutrients such as nitrogen (N), phosphorous (P), and potassium(K) prior to discharge to natural waterway; The three primary components of the system operated in series. Domestic wastewaters were first induced to flow in a spiral pattern in the HBF for removal of O&G. The effluents from HBF were then trickled through the BT filled with perforated cylindrical plastic tubes to provide cross-flow alternated with vertical flow for removal ofSS, NH3-N, BODs and N. The final stage of the system was the FWS that focused on the removal of nutrients (N, P, K) by using a type of Sarawak local water lettuce called "Pistia Stratiotes". From this research, it was found that HBF achieved approximately . 73.54% removal of O&G, while the removal rates of BOD, NH3-N, N, P, K and SS by the biotower (TF) were approximately 35.0%, 57.4%, 51.8%, 13.4%, 21.8%, and 21.9%, respectively. The pollutant removal rates achieved by FWS were approximately 24.1 % BOD, 30.6% NH3-N, 38.0% N, 41.5% P, 46.7% K, and 37.1% SS. The overall combined removal efficiencies of HBF, BT and FWS were approximately 73.5%, 59.2%, 87.9%,90.6%, 54.9%, 68.5%, and 59.0% for O&G, BOD, NH3-N, N, P, K and SS, respectively.
format Thesis
author Oon, Yin Wee.
author_facet Oon, Yin Wee.
author_sort Oon, Yin Wee.
title Development and performance evaluation of A 3-stage treatment system for domestic wastewater
title_short Development and performance evaluation of A 3-stage treatment system for domestic wastewater
title_full Development and performance evaluation of A 3-stage treatment system for domestic wastewater
title_fullStr Development and performance evaluation of A 3-stage treatment system for domestic wastewater
title_full_unstemmed Development and performance evaluation of A 3-stage treatment system for domestic wastewater
title_sort development and performance evaluation of a 3-stage treatment system for domestic wastewater
publisher Universiti Malaysia Sarawak (UNIMAS)
publishDate 2008
url http://ir.unimas.my/id/eprint/30294/1/Oon%20Yin%20Wee%20ft.pdf
http://ir.unimas.my/id/eprint/30294/
_version_ 1769847656791670784
score 13.214268