A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates

Human being appreciate the relief from discomfort afforded by a modern air conditioning system. In the present day, many houses, offices and commercial buildings or facilities would not be comfortable to stay in without control of the indoor air environment. Air conditioning refers to the control of...

Full description

Saved in:
Bibliographic Details
Main Author: Christopher, Jantai Boniface
Format: Thesis
Language:English
Published: unimas 2016
Subjects:
Online Access:http://ir.unimas.my/id/eprint/20997/1/Christopher%20Jantai%20Boniface%20ft.pdf
http://ir.unimas.my/id/eprint/20997/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.20997
record_format eprints
spelling my.unimas.ir.209972023-04-26T08:37:36Z http://ir.unimas.my/id/eprint/20997/ A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates Christopher, Jantai Boniface T Technology (General) TJ Mechanical engineering and machinery Human being appreciate the relief from discomfort afforded by a modern air conditioning system. In the present day, many houses, offices and commercial buildings or facilities would not be comfortable to stay in without control of the indoor air environment. Air conditioning refers to the control of air temperature, moisture content, cleanliness, air quality and air circulation as required by an occupant, a process or a product in the space. The study was divided into three major parts which consists of cooling load calculation method, Indoor Air Quality (IAQ) and flow simulation. The first part involved the comparison of various methods of cooling load calculation for equatorial climates (hot and humid), cooling load calculation suitable for peak load calculation and cooling load energy analysis, implication of under size air conditioning system and cooling load per square meter for specific building (Building functionality).The results on the first part of the study shows that for building with high ceiling and high volume of occupants, it is recommended that the peak cooling loads per square meter shall be between 0.121kW/m2 and 0.159kW/m2.As for offices, it is recommended that the peak cooling load for high efficient buildings are from 0.058kW/m2 to 0.106kW/m2. The second part of the research is on Indoor Air Quality (IAQ) sampling which was conducted during UNIMAS Convocation in year 2012. The sampling of IAQ was successfully completed with collaborations Department of Occupational Safety and Health (DOSH) Ministry Of Human Resources, Malaysia. unimas 2016 Thesis NonPeerReviewed text en http://ir.unimas.my/id/eprint/20997/1/Christopher%20Jantai%20Boniface%20ft.pdf Christopher, Jantai Boniface (2016) A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates. Masters thesis, UNIMAS.
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Christopher, Jantai Boniface
A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates
description Human being appreciate the relief from discomfort afforded by a modern air conditioning system. In the present day, many houses, offices and commercial buildings or facilities would not be comfortable to stay in without control of the indoor air environment. Air conditioning refers to the control of air temperature, moisture content, cleanliness, air quality and air circulation as required by an occupant, a process or a product in the space. The study was divided into three major parts which consists of cooling load calculation method, Indoor Air Quality (IAQ) and flow simulation. The first part involved the comparison of various methods of cooling load calculation for equatorial climates (hot and humid), cooling load calculation suitable for peak load calculation and cooling load energy analysis, implication of under size air conditioning system and cooling load per square meter for specific building (Building functionality).The results on the first part of the study shows that for building with high ceiling and high volume of occupants, it is recommended that the peak cooling loads per square meter shall be between 0.121kW/m2 and 0.159kW/m2.As for offices, it is recommended that the peak cooling load for high efficient buildings are from 0.058kW/m2 to 0.106kW/m2. The second part of the research is on Indoor Air Quality (IAQ) sampling which was conducted during UNIMAS Convocation in year 2012. The sampling of IAQ was successfully completed with collaborations Department of Occupational Safety and Health (DOSH) Ministry Of Human Resources, Malaysia.
format Thesis
author Christopher, Jantai Boniface
author_facet Christopher, Jantai Boniface
author_sort Christopher, Jantai Boniface
title A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates
title_short A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates
title_full A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates
title_fullStr A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates
title_full_unstemmed A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates
title_sort study on radian time series (rts) based method for calculating cooling load in equatorial climates
publisher unimas
publishDate 2016
url http://ir.unimas.my/id/eprint/20997/1/Christopher%20Jantai%20Boniface%20ft.pdf
http://ir.unimas.my/id/eprint/20997/
_version_ 1765301167396487168
score 13.214268