A review on noise suppression and aberration compensation in holographic particle image velocimetry

Understanding three-dimensional (3D) fluid flow behaviour is undeniably crucial in improving performance and efficiency in a wide range of applications in engineering and medical fields. Holographic particle image velocimetry (HPIV) is a potential tool to probe and characterize complex flow dynamics...

Full description

Saved in:
Bibliographic Details
Main Authors: Tamrin, K. F., Rahmatullah, B., Williams, James
Format: Article
Language:English
Published: Cogent OA 2016
Subjects:
Online Access:http://ir.unimas.my/id/eprint/17771/1/Tamrin.pdf
http://ir.unimas.my/id/eprint/17771/
http://dx.doi.org/10.1080/23311940.2016.1142819
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.17771
record_format eprints
spelling my.unimas.ir.177712021-06-09T14:12:11Z http://ir.unimas.my/id/eprint/17771/ A review on noise suppression and aberration compensation in holographic particle image velocimetry Tamrin, K. F. Rahmatullah, B. Williams, James TJ Mechanical engineering and machinery Understanding three-dimensional (3D) fluid flow behaviour is undeniably crucial in improving performance and efficiency in a wide range of applications in engineering and medical fields. Holographic particle image velocimetry (HPIV) is a potential tool to probe and characterize complex flow dynamics since it is a truly three-dimensional three-component measurement technique. The technique relies on the coherent light scattered by small seeding particles that are assumed to faithfully follow the flow for subsequent reconstruction of the same the event afterward. However, extraction of useful 3D displacement data from these particle images is usually aggravated by noise and aberration which are inherent within the optical system. Noise and aberration have been considered as major hurdles in HPIV in obtaining accurate particle image identification and its corresponding 3D position. Major contributions to noise include zero-order diffraction, out-of-focus particles, virtual image and emulsion grain scattering. Noise suppression is crucial to ensure that particle image can be distinctly differentiated from background noise while aberration compensation forms particle image with high integrity. This paper reviews a number of HPIV configurations that have been proposed to address these issues, summarizes the key findings and outlines a basis for follow-on research. Cogent OA 2016 Article PeerReviewed text en http://ir.unimas.my/id/eprint/17771/1/Tamrin.pdf Tamrin, K. F. and Rahmatullah, B. and Williams, James (2016) A review on noise suppression and aberration compensation in holographic particle image velocimetry. Cogent Physics, 3. ISSN 2331-1940 http://dx.doi.org/10.1080/23311940.2016.1142819 Doi : 10.1080/23311940.2016.1142819
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Tamrin, K. F.
Rahmatullah, B.
Williams, James
A review on noise suppression and aberration compensation in holographic particle image velocimetry
description Understanding three-dimensional (3D) fluid flow behaviour is undeniably crucial in improving performance and efficiency in a wide range of applications in engineering and medical fields. Holographic particle image velocimetry (HPIV) is a potential tool to probe and characterize complex flow dynamics since it is a truly three-dimensional three-component measurement technique. The technique relies on the coherent light scattered by small seeding particles that are assumed to faithfully follow the flow for subsequent reconstruction of the same the event afterward. However, extraction of useful 3D displacement data from these particle images is usually aggravated by noise and aberration which are inherent within the optical system. Noise and aberration have been considered as major hurdles in HPIV in obtaining accurate particle image identification and its corresponding 3D position. Major contributions to noise include zero-order diffraction, out-of-focus particles, virtual image and emulsion grain scattering. Noise suppression is crucial to ensure that particle image can be distinctly differentiated from background noise while aberration compensation forms particle image with high integrity. This paper reviews a number of HPIV configurations that have been proposed to address these issues, summarizes the key findings and outlines a basis for follow-on research.
format Article
author Tamrin, K. F.
Rahmatullah, B.
Williams, James
author_facet Tamrin, K. F.
Rahmatullah, B.
Williams, James
author_sort Tamrin, K. F.
title A review on noise suppression and aberration compensation in holographic particle image velocimetry
title_short A review on noise suppression and aberration compensation in holographic particle image velocimetry
title_full A review on noise suppression and aberration compensation in holographic particle image velocimetry
title_fullStr A review on noise suppression and aberration compensation in holographic particle image velocimetry
title_full_unstemmed A review on noise suppression and aberration compensation in holographic particle image velocimetry
title_sort review on noise suppression and aberration compensation in holographic particle image velocimetry
publisher Cogent OA
publishDate 2016
url http://ir.unimas.my/id/eprint/17771/1/Tamrin.pdf
http://ir.unimas.my/id/eprint/17771/
http://dx.doi.org/10.1080/23311940.2016.1142819
_version_ 1702173251089727488
score 13.18916