Under-Frequency Load Shedding (UFLS) Schemes – A Survey

The Under-frequency Load Shedding (UFLS) scheme has been used by utility companies around the world to mitigate frequency drop caused by simultaneous or cascading tripping of transmission lines and/or generators in a power system. In the effort to devise an optimal load shedding scheme, it is impera...

Full description

Saved in:
Bibliographic Details
Main Authors: Lu, M., Wan Azlan, Wan Zainal Abidin, Masri, T., S. Chen, D. H. A. Lee
Format: Article
Language:English
Published: Research India Publications 2016
Subjects:
Online Access:http://ir.unimas.my/id/eprint/11479/1/Under-Frequency%20Load%20Shedding%20%28UFLS%29%20Schemes%20%28abstract%29.pdf
http://ir.unimas.my/id/eprint/11479/
http://www.ripublication.com/ijaer16/ijaerv11n1_70.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir.11479
record_format eprints
spelling my.unimas.ir.114792023-06-12T07:15:37Z http://ir.unimas.my/id/eprint/11479/ Under-Frequency Load Shedding (UFLS) Schemes – A Survey Lu, M. Wan Azlan, Wan Zainal Abidin Masri, T. S. Chen, D. H. A. Lee T Technology (General) TK Electrical engineering. Electronics Nuclear engineering The Under-frequency Load Shedding (UFLS) scheme has been used by utility companies around the world to mitigate frequency drop caused by simultaneous or cascading tripping of transmission lines and/or generators in a power system. In the effort to devise an optimal load shedding scheme, it is imperative that investigations are done on the many factors that may affect the response of the scheme in the event of a system contingency. This paper starts by analysing the implementation of UFLS in various power utility companies in Asia, Europe, Australasia, South Africa, Middle East and the Americas. It is observed that UFLS in these continents differ in terms of total load shed, number of UFLS blocks, average block size and trip frequency deviation thresholds depending on their system size, system inertia and generation mix. This paper also looked at the usage of System Frequency Response (SFR) models in the computation of UFLS and system parameters. Analysis on the SFR model showed that the impact of voltage dependence of loads was not taken into consideration in the early implementation of the model albeit load characteristics have significant influence on the dynamic behaviour of power systems during low frequency oscillation and severe faults. SFR model incorporating frequency and voltage dependence load models was proposed later in literature and used in the design of an optimal UFLS scheme. Investigation was also conducted on UFLS operating philosophies in terms of load shedding trigger, power imbalance estimation and distribution of load shedding. UFLS operating philosophies based solely on frequency parameters is inadequate to determine the stability of a power system especially for an islanded power system following severe disturbances. The power system may be susceptible to voltage collapse as well, which will lead to total system blackout within shorter time duration as compared to a frequency collapse phenomenon. Hence, trigger condition considering voltage information and voltage stability criterions were introduced and implemented in UFLS schemes. Distribution of load shedding based on power flow tracing method catering for both frequency and voltage instabilities was also introduced and proven to give optimal system response Research India Publications 2016 Article PeerReviewed text en http://ir.unimas.my/id/eprint/11479/1/Under-Frequency%20Load%20Shedding%20%28UFLS%29%20Schemes%20%28abstract%29.pdf Lu, M. and Wan Azlan, Wan Zainal Abidin and Masri, T. and S. Chen, D. H. A. Lee (2016) Under-Frequency Load Shedding (UFLS) Schemes – A Survey. International Journal of Applied Engineering Research, 11 (1). pp. 456-472. ISSN 0973-4562 http://www.ripublication.com/ijaer16/ijaerv11n1_70.pdf
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Lu, M.
Wan Azlan, Wan Zainal Abidin
Masri, T.
S. Chen, D. H. A. Lee
Under-Frequency Load Shedding (UFLS) Schemes – A Survey
description The Under-frequency Load Shedding (UFLS) scheme has been used by utility companies around the world to mitigate frequency drop caused by simultaneous or cascading tripping of transmission lines and/or generators in a power system. In the effort to devise an optimal load shedding scheme, it is imperative that investigations are done on the many factors that may affect the response of the scheme in the event of a system contingency. This paper starts by analysing the implementation of UFLS in various power utility companies in Asia, Europe, Australasia, South Africa, Middle East and the Americas. It is observed that UFLS in these continents differ in terms of total load shed, number of UFLS blocks, average block size and trip frequency deviation thresholds depending on their system size, system inertia and generation mix. This paper also looked at the usage of System Frequency Response (SFR) models in the computation of UFLS and system parameters. Analysis on the SFR model showed that the impact of voltage dependence of loads was not taken into consideration in the early implementation of the model albeit load characteristics have significant influence on the dynamic behaviour of power systems during low frequency oscillation and severe faults. SFR model incorporating frequency and voltage dependence load models was proposed later in literature and used in the design of an optimal UFLS scheme. Investigation was also conducted on UFLS operating philosophies in terms of load shedding trigger, power imbalance estimation and distribution of load shedding. UFLS operating philosophies based solely on frequency parameters is inadequate to determine the stability of a power system especially for an islanded power system following severe disturbances. The power system may be susceptible to voltage collapse as well, which will lead to total system blackout within shorter time duration as compared to a frequency collapse phenomenon. Hence, trigger condition considering voltage information and voltage stability criterions were introduced and implemented in UFLS schemes. Distribution of load shedding based on power flow tracing method catering for both frequency and voltage instabilities was also introduced and proven to give optimal system response
format Article
author Lu, M.
Wan Azlan, Wan Zainal Abidin
Masri, T.
S. Chen, D. H. A. Lee
author_facet Lu, M.
Wan Azlan, Wan Zainal Abidin
Masri, T.
S. Chen, D. H. A. Lee
author_sort Lu, M.
title Under-Frequency Load Shedding (UFLS) Schemes – A Survey
title_short Under-Frequency Load Shedding (UFLS) Schemes – A Survey
title_full Under-Frequency Load Shedding (UFLS) Schemes – A Survey
title_fullStr Under-Frequency Load Shedding (UFLS) Schemes – A Survey
title_full_unstemmed Under-Frequency Load Shedding (UFLS) Schemes – A Survey
title_sort under-frequency load shedding (ufls) schemes – a survey
publisher Research India Publications
publishDate 2016
url http://ir.unimas.my/id/eprint/11479/1/Under-Frequency%20Load%20Shedding%20%28UFLS%29%20Schemes%20%28abstract%29.pdf
http://ir.unimas.my/id/eprint/11479/
http://www.ripublication.com/ijaer16/ijaerv11n1_70.pdf
_version_ 1769847610473971712