An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP)

A coal-fired flue gas contains high concentrations of fine particles which can pose a threat to the environment. In this study, an electrostatic precipitator is used to remove the fine particles of the flue gas from a 100MW coal fired power plant by using a model. A model has been presented to estim...

Full description

Saved in:
Bibliographic Details
Main Authors: Shanti Faridah, Salleh, Afrasyab, Khan, Cirilo Nolasco, Hipolito, Lennevey, Kinidi, Dayang Siti Herdawati, Abang Hardin
Format: Article
Language:English
Published: Penerbit UTM Press Universiti Teknologi Malaysia 2019
Subjects:
Online Access:http://ir.unimas.my/id/eprint/46392/1/An_Analytical_Modeling_Approach_for_Perf.pdf
http://ir.unimas.my/id/eprint/46392/
https://jest.utm.my/index.php/jest/article/view/33
https://doi.org/10.11113/jest.v1n2-2.33
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimas.ir-46392
record_format eprints
spelling my.unimas.ir-463922024-10-18T06:48:56Z http://ir.unimas.my/id/eprint/46392/ An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP) Shanti Faridah, Salleh Afrasyab, Khan Cirilo Nolasco, Hipolito Lennevey, Kinidi Dayang Siti Herdawati, Abang Hardin TP Chemical technology A coal-fired flue gas contains high concentrations of fine particles which can pose a threat to the environment. In this study, an electrostatic precipitator is used to remove the fine particles of the flue gas from a 100MW coal fired power plant by using a model. A model has been presented to estimate the performance of the wet electrostatic precipitator (WEP) in terms of the number of plates, flow rates and velocity. The equations have been specified for the charging and charge on the single particle of some definite diameter. The effect of the measuring points for the calculation of the effective migration velocities and hence overall performance along with the re-entrainment and gas sneakage have been incorporated. Ranges for the above-mentioned parameters are well defined and it has been observed that after a certain range values across number of plates, velocities and flow rates there is no significant improvement in the performance of the WEP has been calculated. Penerbit UTM Press Universiti Teknologi Malaysia 2019-02-10 Article PeerReviewed text en http://ir.unimas.my/id/eprint/46392/1/An_Analytical_Modeling_Approach_for_Perf.pdf Shanti Faridah, Salleh and Afrasyab, Khan and Cirilo Nolasco, Hipolito and Lennevey, Kinidi and Dayang Siti Herdawati, Abang Hardin (2019) An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP). Journal of Energy and Safety Technology, 1 (2-2). 63 -73. ISSN 2637-1030 https://jest.utm.my/index.php/jest/article/view/33 https://doi.org/10.11113/jest.v1n2-2.33
institution Universiti Malaysia Sarawak
building Centre for Academic Information Services (CAIS)
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Sarawak
content_source UNIMAS Institutional Repository
url_provider http://ir.unimas.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Shanti Faridah, Salleh
Afrasyab, Khan
Cirilo Nolasco, Hipolito
Lennevey, Kinidi
Dayang Siti Herdawati, Abang Hardin
An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP)
description A coal-fired flue gas contains high concentrations of fine particles which can pose a threat to the environment. In this study, an electrostatic precipitator is used to remove the fine particles of the flue gas from a 100MW coal fired power plant by using a model. A model has been presented to estimate the performance of the wet electrostatic precipitator (WEP) in terms of the number of plates, flow rates and velocity. The equations have been specified for the charging and charge on the single particle of some definite diameter. The effect of the measuring points for the calculation of the effective migration velocities and hence overall performance along with the re-entrainment and gas sneakage have been incorporated. Ranges for the above-mentioned parameters are well defined and it has been observed that after a certain range values across number of plates, velocities and flow rates there is no significant improvement in the performance of the WEP has been calculated.
format Article
author Shanti Faridah, Salleh
Afrasyab, Khan
Cirilo Nolasco, Hipolito
Lennevey, Kinidi
Dayang Siti Herdawati, Abang Hardin
author_facet Shanti Faridah, Salleh
Afrasyab, Khan
Cirilo Nolasco, Hipolito
Lennevey, Kinidi
Dayang Siti Herdawati, Abang Hardin
author_sort Shanti Faridah, Salleh
title An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP)
title_short An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP)
title_full An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP)
title_fullStr An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP)
title_full_unstemmed An Analytical Modeling Approach for Performance Evaluation of Electrostatic Precipitator (ESP)
title_sort analytical modeling approach for performance evaluation of electrostatic precipitator (esp)
publisher Penerbit UTM Press Universiti Teknologi Malaysia
publishDate 2019
url http://ir.unimas.my/id/eprint/46392/1/An_Analytical_Modeling_Approach_for_Perf.pdf
http://ir.unimas.my/id/eprint/46392/
https://jest.utm.my/index.php/jest/article/view/33
https://doi.org/10.11113/jest.v1n2-2.33
_version_ 1814942165742125056
score 13.214268