Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint

The power losses occurring under magnetising condition have received a great deal of attention for a long time. The transformer designs with Butt Lap joint cause the highest power loss at the T-joint. These due to the flux need to rotate 90º into the hard direction and transfer up and down to the ad...

Full description

Saved in:
Bibliographic Details
Main Author: Shuhaimi, Zakaria@Abdullah
Format: Thesis
Language:English
Published: Universiti Malaysia Perlis (UniMAP) 2010
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/9811
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-9811
record_format dspace
spelling my.unimap-98112010-10-13T07:52:05Z Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint Shuhaimi, Zakaria@Abdullah T-joint Flux density Power loss Transformer 100kVA Distribution Transformer The power losses occurring under magnetising condition have received a great deal of attention for a long time. The transformer designs with Butt Lap joint cause the highest power loss at the T-joint. These due to the flux need to rotate 90º into the hard direction and transfer up and down to the adjacent layers causes high rotational power loss occurred at the T-joint. To overcome this problem, the different cutting angle such as 23º, 45 º and 60º at the T-joint was introduces in order to find out the most efficient design. The development of the 100kVA Distribution Transformer model core with the four difference types of the T-joint for the power loss and building factor measurement has been tested in order to find which T-joint has minimum power loss and better building factor. The localised flux density was measured using the search coil in order to find out their distribution at the corner joint and T-joint. The fundamental, third and fifth harmonic in the normal and inplane flux density were measured at the corner joint and T-joint. The localised power loss was measured using the thermistor at the similar location of the search coil. The results show that the minimum power loss, better building factor, the minimum fundamental, third and fifth harmonic the normal and inplane flux density and also minimum localised power loss are occurred at the transformer model core assembled with the 60° T-joint. 2010-10-13T07:52:05Z 2010-10-13T07:52:05Z 2010 Thesis http://hdl.handle.net/123456789/9811 en Universiti Malaysia Perlis (UniMAP) School of Electrical Systems Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic T-joint
Flux density
Power loss
Transformer
100kVA Distribution Transformer
spellingShingle T-joint
Flux density
Power loss
Transformer
100kVA Distribution Transformer
Shuhaimi, Zakaria@Abdullah
Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint
description The power losses occurring under magnetising condition have received a great deal of attention for a long time. The transformer designs with Butt Lap joint cause the highest power loss at the T-joint. These due to the flux need to rotate 90º into the hard direction and transfer up and down to the adjacent layers causes high rotational power loss occurred at the T-joint. To overcome this problem, the different cutting angle such as 23º, 45 º and 60º at the T-joint was introduces in order to find out the most efficient design. The development of the 100kVA Distribution Transformer model core with the four difference types of the T-joint for the power loss and building factor measurement has been tested in order to find which T-joint has minimum power loss and better building factor. The localised flux density was measured using the search coil in order to find out their distribution at the corner joint and T-joint. The fundamental, third and fifth harmonic in the normal and inplane flux density were measured at the corner joint and T-joint. The localised power loss was measured using the thermistor at the similar location of the search coil. The results show that the minimum power loss, better building factor, the minimum fundamental, third and fifth harmonic the normal and inplane flux density and also minimum localised power loss are occurred at the transformer model core assembled with the 60° T-joint.
format Thesis
author Shuhaimi, Zakaria@Abdullah
author_facet Shuhaimi, Zakaria@Abdullah
author_sort Shuhaimi, Zakaria@Abdullah
title Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint
title_short Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint
title_full Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint
title_fullStr Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint
title_full_unstemmed Flux density and power loss distribution in 100kVA Distribution Transformer core assembled with different cutting angle of T-joint
title_sort flux density and power loss distribution in 100kva distribution transformer core assembled with different cutting angle of t-joint
publisher Universiti Malaysia Perlis (UniMAP)
publishDate 2010
url http://dspace.unimap.edu.my/xmlui/handle/123456789/9811
_version_ 1643789652746829824
score 13.214268