Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang.
Saved in:
Main Authors: | , , |
---|---|
Format: | Working Paper |
Language: | English |
Published: |
Universiti Malaysia Pahang (UMP)
2010
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/8622 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-8622 |
---|---|
record_format |
dspace |
spelling |
my.unimap-86222010-08-12T06:31:11Z Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint Ismail, Daut, Prof. Dr. Dina Maizana, MT M., Ahmad Transformer core Temperature rise Thermistor Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. This paper describes the result of measurement of localised temperature rise on 100kVA 3phase distribution transformer assembled with 90o T-joint and mitred lap corner joint with stagger yoke with overlap length of 10mm. The measurement involves the initial temperature and last temperature after 20 minutes experiment. The temperature rises have been measured using no load test by arrays of thermistor on M5 (CGO) grades material of transformer core laminations. The localised temperature rise at the outer 90o T-joint is 0.075 oC/minutes and rises to be 0.095 oC/minutes at the inner 90o T-joint when the transformer core energized 1.5 T 50Hz. A small amount of flux deviation from the rolling direction occurs at the overlap. 2010-08-12T06:31:11Z 2010-08-12T06:31:11Z 2009-06-20 Working Paper p.1-3 http://hdl.handle.net/123456789/8622 en Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) 2009 Universiti Malaysia Pahang (UMP) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Transformer core Temperature rise Thermistor Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) |
spellingShingle |
Transformer core Temperature rise Thermistor Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) Ismail, Daut, Prof. Dr. Dina Maizana, MT M., Ahmad Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint |
description |
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. |
format |
Working Paper |
author |
Ismail, Daut, Prof. Dr. Dina Maizana, MT M., Ahmad |
author_facet |
Ismail, Daut, Prof. Dr. Dina Maizana, MT M., Ahmad |
author_sort |
Ismail, Daut, Prof. Dr. |
title |
Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint |
title_short |
Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint |
title_full |
Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint |
title_fullStr |
Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint |
title_full_unstemmed |
Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint |
title_sort |
gradient temperature on 3phase transformer core with staggered yoke with 90 t-joint |
publisher |
Universiti Malaysia Pahang (UMP) |
publishDate |
2010 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/8622 |
_version_ |
1643789271379738624 |
score |
13.214268 |