Failure analysis on skunk-arm of electrical tower
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang.
Saved in:
Main Authors: | , |
---|---|
Format: | Working Paper |
Language: | English |
Published: |
Universiti Malaysia Pahang (UMP)
2010
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/8535 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-8535 |
---|---|
record_format |
dspace |
spelling |
my.unimap-85352010-08-11T02:27:33Z Failure analysis on skunk-arm of electrical tower Ahmad, Rivai Md Radzai, Said Skunk-arm Failure Buckling Bending Finite Elements Analysis MUCEET Malaysian Technical Universities Conference on Engineering and Technology MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. Un-proper procedure during installation of the wire-rope could introduce unusual loading to the skunk-arm of the highvoltage electrical tower. Understanding of structural behavior of this kind of structure under different loading should be helpful to take preventive measure again possible future accidental cases. Static and buckling analyses have been performed using Finite Elements Analysis (FEA). Skunk-arm structure modelized by one-dimensional elements, combination between bar and beam. Beam elements represent main structure that are flexural members and bar elements represent stiffener that can only be in tension or compression loading. Stress distribution due to maximum static loading did not show an excessive stress value, it means no yielding occurs in the structure. But buckling factor show the maximum loading is close to the critical loading that may provoke collapse of structure in buckling mode. The result show the mechanism of structure failure, which begin with buckling of the lower members of the skunk. In normal condition, factor of safety of 2 is taken according to maximum loading of the structure. 2010-08-11T02:27:33Z 2010-08-11T02:27:33Z 2009-06-20 Working Paper p.83-86 http://hdl.handle.net/123456789/8535 en Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) 2009 Universiti Malaysia Pahang (UMP) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Skunk-arm Failure Buckling Bending Finite Elements Analysis MUCEET Malaysian Technical Universities Conference on Engineering and Technology |
spellingShingle |
Skunk-arm Failure Buckling Bending Finite Elements Analysis MUCEET Malaysian Technical Universities Conference on Engineering and Technology Ahmad, Rivai Md Radzai, Said Failure analysis on skunk-arm of electrical tower |
description |
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. |
format |
Working Paper |
author |
Ahmad, Rivai Md Radzai, Said |
author_facet |
Ahmad, Rivai Md Radzai, Said |
author_sort |
Ahmad, Rivai |
title |
Failure analysis on skunk-arm of electrical tower |
title_short |
Failure analysis on skunk-arm of electrical tower |
title_full |
Failure analysis on skunk-arm of electrical tower |
title_fullStr |
Failure analysis on skunk-arm of electrical tower |
title_full_unstemmed |
Failure analysis on skunk-arm of electrical tower |
title_sort |
failure analysis on skunk-arm of electrical tower |
publisher |
Universiti Malaysia Pahang (UMP) |
publishDate |
2010 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/8535 |
_version_ |
1643789228274876416 |
score |
13.222552 |