Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1

MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang.

Saved in:
Bibliographic Details
Main Authors: Nor Akmal, Mohd Jamail, Zainal Alam, Haron, Asmarashid, Poniran, Qamarul Ezani, Kamarudin, Nor Anija, Jamaludin
Format: Working Paper
Language:English
Published: Universiti Malaysia Pahang (UMP) 2010
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/8523
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-8523
record_format dspace
spelling my.unimap-85232010-08-11T01:03:44Z Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 Nor Akmal, Mohd Jamail Zainal Alam, Haron Asmarashid, Poniran Qamarul Ezani, Kamarudin Nor Anija, Jamaludin Partial discharge XLPE cable Electrical discharge MUCEET Malaysian Technical Universities Conference on Engineering and Technology MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. High voltage insulation breakdown has been the main causes of high voltage system breakdown. It is found that this phenomenon occurs due to the existence of partial discharge within voids found in the insulation of XLPE cables, which is produced accidentally during the extrusion process of the cables. The effect of partial discharge would lead to serious breakdown of power cable systems and electrical apparatus failures. Many appropriate techniques can be used to evaluate the condition of XLPE cables. One of the techniques is partial discharge testing. This study focuses on 11 kV XLPE cables and the partial discharge testing is conducted using partial discharge detector equipment. The analysis of data shows that the partial discharge test can be used to evaluate the performance and behaviour of the XLPE cable. The finding shows, if the partial discharge value for the cable is more than 10 pC, the cable is considered failed and it is not safe to be used. 2010-08-11T01:03:44Z 2010-08-11T01:03:44Z 2009-06-20 Working Paper p.27-30 http://hdl.handle.net/123456789/8523 en Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) 2009 Universiti Malaysia Pahang (UMP)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Partial discharge
XLPE cable
Electrical discharge
MUCEET
Malaysian Technical Universities Conference on Engineering and Technology
spellingShingle Partial discharge
XLPE cable
Electrical discharge
MUCEET
Malaysian Technical Universities Conference on Engineering and Technology
Nor Akmal, Mohd Jamail
Zainal Alam, Haron
Asmarashid, Poniran
Qamarul Ezani, Kamarudin
Nor Anija, Jamaludin
Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1
description MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang.
format Working Paper
author Nor Akmal, Mohd Jamail
Zainal Alam, Haron
Asmarashid, Poniran
Qamarul Ezani, Kamarudin
Nor Anija, Jamaludin
author_facet Nor Akmal, Mohd Jamail
Zainal Alam, Haron
Asmarashid, Poniran
Qamarul Ezani, Kamarudin
Nor Anija, Jamaludin
author_sort Nor Akmal, Mohd Jamail
title Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1
title_short Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1
title_full Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1
title_fullStr Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1
title_full_unstemmed Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1
title_sort partial discharge detection for condition monitoring of an 11-kv xlpe cable – part 1
publisher Universiti Malaysia Pahang (UMP)
publishDate 2010
url http://dspace.unimap.edu.my/xmlui/handle/123456789/8523
_version_ 1643789224135098368
score 13.209306