Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang.
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Working Paper |
Language: | English |
Published: |
Universiti Malaysia Pahang (UMP)
2010
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/8523 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-8523 |
---|---|
record_format |
dspace |
spelling |
my.unimap-85232010-08-11T01:03:44Z Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 Nor Akmal, Mohd Jamail Zainal Alam, Haron Asmarashid, Poniran Qamarul Ezani, Kamarudin Nor Anija, Jamaludin Partial discharge XLPE cable Electrical discharge MUCEET Malaysian Technical Universities Conference on Engineering and Technology MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. High voltage insulation breakdown has been the main causes of high voltage system breakdown. It is found that this phenomenon occurs due to the existence of partial discharge within voids found in the insulation of XLPE cables, which is produced accidentally during the extrusion process of the cables. The effect of partial discharge would lead to serious breakdown of power cable systems and electrical apparatus failures. Many appropriate techniques can be used to evaluate the condition of XLPE cables. One of the techniques is partial discharge testing. This study focuses on 11 kV XLPE cables and the partial discharge testing is conducted using partial discharge detector equipment. The analysis of data shows that the partial discharge test can be used to evaluate the performance and behaviour of the XLPE cable. The finding shows, if the partial discharge value for the cable is more than 10 pC, the cable is considered failed and it is not safe to be used. 2010-08-11T01:03:44Z 2010-08-11T01:03:44Z 2009-06-20 Working Paper p.27-30 http://hdl.handle.net/123456789/8523 en Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCEET) 2009 Universiti Malaysia Pahang (UMP) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Partial discharge XLPE cable Electrical discharge MUCEET Malaysian Technical Universities Conference on Engineering and Technology |
spellingShingle |
Partial discharge XLPE cable Electrical discharge MUCEET Malaysian Technical Universities Conference on Engineering and Technology Nor Akmal, Mohd Jamail Zainal Alam, Haron Asmarashid, Poniran Qamarul Ezani, Kamarudin Nor Anija, Jamaludin Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 |
description |
MUCEET 2009 is organized by Malaysian Technical Universities Network (MTUN) comprising of Universiti Malaysia Perlis (UniMAP), Universiti Tun Hussein Onn (UTHM), Universiti Teknikal Melaka (UTeM) and Universiti Malaysia Pahang (UMP), 20th - 22nd June 2009 at M. S. Garden Hotel, Kuantan, Pahang. |
format |
Working Paper |
author |
Nor Akmal, Mohd Jamail Zainal Alam, Haron Asmarashid, Poniran Qamarul Ezani, Kamarudin Nor Anija, Jamaludin |
author_facet |
Nor Akmal, Mohd Jamail Zainal Alam, Haron Asmarashid, Poniran Qamarul Ezani, Kamarudin Nor Anija, Jamaludin |
author_sort |
Nor Akmal, Mohd Jamail |
title |
Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 |
title_short |
Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 |
title_full |
Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 |
title_fullStr |
Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 |
title_full_unstemmed |
Partial discharge detection for condition monitoring of an 11-kV XLPE cable – Part 1 |
title_sort |
partial discharge detection for condition monitoring of an 11-kv xlpe cable – part 1 |
publisher |
Universiti Malaysia Pahang (UMP) |
publishDate |
2010 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/8523 |
_version_ |
1643789224135098368 |
score |
13.209306 |