The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature

Link to publisher's homepage at http://ijneam.unimap.edu.my

Saved in:
Bibliographic Details
Main Authors: Mohamad Firdaus, Sukri, Rusmiati, Lokman, Asjufri, Muhajir, Faizil, Wasbari, Amir Abdullah, Muhamad Damanhur, Kasni, Sumeru
Other Authors: mohdfirdaus@utem.edu.my
Format: Article
Language:English
Published: Universiti Malaysia Perlis (UniMAP) 2020
Subjects:
Online Access:http://dspace.unimap.edu.my:80/xmlui/handle/123456789/68803
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-68803
record_format dspace
spelling my.unimap-688032020-12-03T03:37:42Z The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature Mohamad Firdaus, Sukri Rusmiati, Lokman Asjufri, Muhajir Faizil, Wasbari Amir Abdullah, Muhamad Damanhur Kasni, Sumeru mohdfirdaus@utem.edu.my Vapour compression refrigeration cycle Air conditioning system Condensate water Sub-cooling method COP improvement Link to publisher's homepage at http://ijneam.unimap.edu.my This paper experimentally investigates the effect of condensate water on the performance of automotive air conditioning (AAC) system under difference evaporator air inlet temperature. An experimental test rig was fabricated using the actual component of AAC system used for Proton Wira passenger car. During experimental work, the volume flow rate of condensate water was manipulated at 0, 140 and 340 ml/min. The evaporator air inlet temperature was also varied at 28, 32 and 36°C. The other parameters of compressor speed, condensate water temperature and condenser air inlet temperature were kept constant at 1550 rpm, 29 ± 1°C and 32 ± 1°C, respectively. The study showed that the coefficient of performance (COP) of the AAC system increases when the volume flow rate of condensate water increased from 0 to 140 ml/min. It was due to a dominant decrease in compressor work, as compared to the drop in cooling capacity. In addition, the highest increment in COP occurred at evaporator air inlet temperature of 36°C (9.8%), followed by evaporator air inlet temperature of 28°C (2.8%) and 32°C (0.4%). The highest COP is 3.66, occurred at evaporator air inlet temperature of 32°C and volume flow rate of condensate water of around 140 ml/min. 2020-12-03T03:37:42Z 2020-12-03T03:37:42Z 2020-05 Article International Journal of Nanoelectronics and Materials, vol.13(Special Issue), 2020, pages 85-94 1985-5761 (Printed) 1997-4434 (Online) http://dspace.unimap.edu.my:80/xmlui/handle/123456789/68803 http://ijneam.unimap.edu.my en International Symposium on Science, Technology and Engineering (ISSTE 2019); Universiti Malaysia Perlis (UniMAP)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Vapour compression refrigeration cycle
Air conditioning system
Condensate water
Sub-cooling method
COP improvement
spellingShingle Vapour compression refrigeration cycle
Air conditioning system
Condensate water
Sub-cooling method
COP improvement
Mohamad Firdaus, Sukri
Rusmiati, Lokman
Asjufri, Muhajir
Faizil, Wasbari
Amir Abdullah, Muhamad Damanhur
Kasni, Sumeru
The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
description Link to publisher's homepage at http://ijneam.unimap.edu.my
author2 mohdfirdaus@utem.edu.my
author_facet mohdfirdaus@utem.edu.my
Mohamad Firdaus, Sukri
Rusmiati, Lokman
Asjufri, Muhajir
Faizil, Wasbari
Amir Abdullah, Muhamad Damanhur
Kasni, Sumeru
format Article
author Mohamad Firdaus, Sukri
Rusmiati, Lokman
Asjufri, Muhajir
Faizil, Wasbari
Amir Abdullah, Muhamad Damanhur
Kasni, Sumeru
author_sort Mohamad Firdaus, Sukri
title The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
title_short The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
title_full The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
title_fullStr The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
title_full_unstemmed The effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
title_sort effect of condensate water on the performance of automotive air conditioning system under difference evaporator air inlet temperature
publisher Universiti Malaysia Perlis (UniMAP)
publishDate 2020
url http://dspace.unimap.edu.my:80/xmlui/handle/123456789/68803
_version_ 1698698523714781184
score 13.214268