Simulation of shunt capacitor switching transient
Master of Electric Power
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2019
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/63413 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-63413 |
---|---|
record_format |
dspace |
spelling |
my.unimap-634132019-11-26T05:04:01Z Simulation of shunt capacitor switching transient Ismael Husein, Almabrouk Dr. Haziah Abdul Hamid Capacitor Power system Capacitor banks Electric reactors, Shunt Master of Electric Power Energization of capacitor banks and shunt reactors has been recognized as a possible source of malfunctions due to the known effect of Switching Transient. Switching transient can produce unwanted high currents with different frequencies that can harm the system in different ways.Modem controlled switching techniques have been developed to reduce switching unwanted effects. Theses modem techniques are based on the fact that if switching operation takes place at a point-on-wave, then it can minimize effectively the effect of switching transient. Theoretically, the controlled switching techniques shall eliminate the switching transients totally. However, current statistics and researches show that the characteristics of the controller and the circuitbreaker itself can affect the success of this method. Therefore, basic understanding of all transients produces during switching process shall be studied taking into consideration all possible parameters and effects. Therefore it was necessary to use the modem computational techniques to solve to a high fidelity nonlinear mathematical model for the transient effect. In this work we used the numerical method applied by A TP software to investigate the transient effect on the quality and quantity of system. Investigations for the cases of Energization inrush, Back to back switching, Outrush Transient, Voltage Magnification and Transient Recovery Voltages was done. The important results are the fact that the transient can be modelled including all parameters and components in such a way that the effect of transient can be minimum. The pivotal identification properties of the transients definitely can be used to improve design characteristics and controlling parameters. 2019-11-26T05:04:01Z 2019-11-26T05:04:01Z 2014 Thesis http://dspace.unimap.edu.my:80/xmlui/handle/123456789/63413 en Universiti Malaysia Perlis (UniMAP) School of Electrical Systems Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Capacitor Power system Capacitor banks Electric reactors, Shunt |
spellingShingle |
Capacitor Power system Capacitor banks Electric reactors, Shunt Ismael Husein, Almabrouk Simulation of shunt capacitor switching transient |
description |
Master of Electric Power |
author2 |
Dr. Haziah Abdul Hamid |
author_facet |
Dr. Haziah Abdul Hamid Ismael Husein, Almabrouk |
format |
Thesis |
author |
Ismael Husein, Almabrouk |
author_sort |
Ismael Husein, Almabrouk |
title |
Simulation of shunt capacitor switching transient |
title_short |
Simulation of shunt capacitor switching transient |
title_full |
Simulation of shunt capacitor switching transient |
title_fullStr |
Simulation of shunt capacitor switching transient |
title_full_unstemmed |
Simulation of shunt capacitor switching transient |
title_sort |
simulation of shunt capacitor switching transient |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2019 |
url |
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/63413 |
_version_ |
1651868840562262016 |
score |
13.214268 |