Different total harmonic distortion effects on current transformer performance
Link to publisher's homepage at http://jere.unimap.edu.my
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2017
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/50511 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-50511 |
---|---|
record_format |
dspace |
spelling |
my.unimap-505112017-11-24T04:05:04Z Different total harmonic distortion effects on current transformer performance Khairul Anuar, Mohd Nor Ismail, Daut Indra, Nisja Mohd Hafiz, Arshad pucheho7@yahoo.com Current transformer Total Harmonic Distortion Non-linear loads Saturation PSCAD Link to publisher's homepage at http://jere.unimap.edu.my The used on non-linear loads devices such as rectifiers, converters or power suppliers in industrial system has increased accordance to the present technology. However non-linear loads are the main problem that suppliers harmonic distortions into the distribution system. Current Transformer is one of protective equipment which will effects when harmonic exist in power system. Total harmonic distortion also can cause the current transformer saturation. This research work investigates the current transformer performance when supplied with difference percentage of total harmonic distortion. Percentage ratio error of current transformer is measured to obtain the accuracy and efficiency of the current transformer. Power System Computer Aided Design (PSCAD) software use to construct, model and simulate the current transformer circuit with total harmonic distortion. The laboratory test with same parameters as simulation software is done to prove the theory state. The current transformer with ratio 15/1A and secondary burden was selected in this research. 2017-11-24T04:05:03Z 2017-11-24T04:05:03Z 2012 Article Journal of Engineering Research and Education, vol. 6, 2012, pages 57-70 1823-2981 http://dspace.unimap.edu.my:80/xmlui/handle/123456789/50511 http://jere.unimap.edu.my en Universiti Malaysia Perlis (UniMAP) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Current transformer Total Harmonic Distortion Non-linear loads Saturation PSCAD |
spellingShingle |
Current transformer Total Harmonic Distortion Non-linear loads Saturation PSCAD Khairul Anuar, Mohd Nor Ismail, Daut Indra, Nisja Mohd Hafiz, Arshad Different total harmonic distortion effects on current transformer performance |
description |
Link to publisher's homepage at http://jere.unimap.edu.my |
author2 |
pucheho7@yahoo.com |
author_facet |
pucheho7@yahoo.com Khairul Anuar, Mohd Nor Ismail, Daut Indra, Nisja Mohd Hafiz, Arshad |
format |
Article |
author |
Khairul Anuar, Mohd Nor Ismail, Daut Indra, Nisja Mohd Hafiz, Arshad |
author_sort |
Khairul Anuar, Mohd Nor |
title |
Different total harmonic distortion effects on current transformer performance |
title_short |
Different total harmonic distortion effects on current transformer performance |
title_full |
Different total harmonic distortion effects on current transformer performance |
title_fullStr |
Different total harmonic distortion effects on current transformer performance |
title_full_unstemmed |
Different total harmonic distortion effects on current transformer performance |
title_sort |
different total harmonic distortion effects on current transformer performance |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2017 |
url |
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/50511 |
_version_ |
1643802893574209536 |
score |
13.222552 |