The application of phase and ground distance relay to three terminal lines
Access is limited to UniMAP community.
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis
2009
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/4399 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-4399 |
---|---|
record_format |
dspace |
spelling |
my.unimap-43992009-02-02T03:43:28Z The application of phase and ground distance relay to three terminal lines Mohd Shah Rizan Ahmad Maidin Abdul Rahim Abdul Razak Distance relay Electric power system Power system network Fault Electric power distribution Electric lines Access is limited to UniMAP community. Distance relay is one of three methods to protect the transmission lines from fault. It consists of two functions which are phase distance functions and ground distance functions. The other two ways to protect the transmission lines is by using overcurrent relay dan pilot relaying. The main problems are to determine the setting of the distance functions. So the apparent impedance seen by distance relay for various system and fault is one of the way to solve the problem. In this project , there are three aspects of application on distance relay to three terminal lines will be studied. The three aspects is phase distance functions, ground distance functions and blocking functions. In this study ,the MATLAB/SIMULINK is used. SIMULINK’s Power System Blockset (PSB) is used for detailed modelling of a power system network and fault simulation. From the modeling ,there are some graph that will be analyzed which are the graph for current phasor , voltage phasor , zone 1 fault and zone 2 fault. 2009-02-02T03:43:28Z 2009-02-02T03:43:28Z 2008-05 Learning Object http://hdl.handle.net/123456789/4399 en Universiti Malaysia Perlis School of Electrical Systems Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Distance relay Electric power system Power system network Fault Electric power distribution Electric lines |
spellingShingle |
Distance relay Electric power system Power system network Fault Electric power distribution Electric lines Mohd Shah Rizan Ahmad Maidin The application of phase and ground distance relay to three terminal lines |
description |
Access is limited to UniMAP community. |
author2 |
Abdul Rahim Abdul Razak |
author_facet |
Abdul Rahim Abdul Razak Mohd Shah Rizan Ahmad Maidin |
format |
Learning Object |
author |
Mohd Shah Rizan Ahmad Maidin |
author_sort |
Mohd Shah Rizan Ahmad Maidin |
title |
The application of phase and ground distance relay to three terminal lines |
title_short |
The application of phase and ground distance relay to three terminal lines |
title_full |
The application of phase and ground distance relay to three terminal lines |
title_fullStr |
The application of phase and ground distance relay to three terminal lines |
title_full_unstemmed |
The application of phase and ground distance relay to three terminal lines |
title_sort |
application of phase and ground distance relay to three terminal lines |
publisher |
Universiti Malaysia Perlis |
publishDate |
2009 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/4399 |
_version_ |
1643788103908851712 |
score |
13.214268 |