Voltage sags and interruptions in a distribution system

Access is limited to UniMAP community.

Saved in:
Bibliographic Details
Main Author: Nur Zahirah Mohd Ali
Other Authors: Surya Hardi Amrin, Ir. (Advisor)
Format: Learning Object
Language:English
Published: Universiti Malaysia Perlis 2009
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/4267
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-4267
record_format dspace
spelling my.unimap-42672009-01-28T09:10:02Z Voltage sags and interruptions in a distribution system Nur Zahirah Mohd Ali Surya Hardi Amrin, Ir. (Advisor) Power quality Electric utilities Electric power distribution Voltage sag Electric power systems Electric power failures Electric power systems -- Analysis Access is limited to UniMAP community. Voltage sag is the important factor in power quality problem faced by many industrial customers. The most frequently reported among various types of power quality disturbance are voltage sags. The disturbance will cause the sensitive load/equipment (adjustable speed drive, contactor starter in motor, etc) to drop out. The main source of voltage sags are faults on the utility system and motor starting. Voltage sag caused by faults is generally more severe than those caused by starting. Voltage sag is normally characterized by a magnitude and duration. The load sensitivity is generally determined by the both values. The sag magnitude is depending on fault location and fault type. The sag duration depends on the clearing time the protective device used. This paper discusses estimation of voltage sag caused by fault in distribution systems that supplied to the sensitive load and sag duration can be controlled using protective device. The result shows that the faults on the adjacent sensitive load are more severe and sensitive load protected by protective device characteristics with longer operating time will most likely to drop out. Analysis of voltage sag is needed to know voltage sag characteristic, because the equipment sensitivity is influenced by the characteristic. This paper is also presents the calculation result of analysis of voltage sags that carried out in a distribution system model by using the software MATLAB. 2009-01-28T09:10:02Z 2009-01-28T09:10:02Z 2008-05 Learning Object http://hdl.handle.net/123456789/4267 en Universiti Malaysia Perlis School of Electrical Systems Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Power quality
Electric utilities
Electric power distribution
Voltage sag
Electric power systems
Electric power failures
Electric power systems -- Analysis
spellingShingle Power quality
Electric utilities
Electric power distribution
Voltage sag
Electric power systems
Electric power failures
Electric power systems -- Analysis
Nur Zahirah Mohd Ali
Voltage sags and interruptions in a distribution system
description Access is limited to UniMAP community.
author2 Surya Hardi Amrin, Ir. (Advisor)
author_facet Surya Hardi Amrin, Ir. (Advisor)
Nur Zahirah Mohd Ali
format Learning Object
author Nur Zahirah Mohd Ali
author_sort Nur Zahirah Mohd Ali
title Voltage sags and interruptions in a distribution system
title_short Voltage sags and interruptions in a distribution system
title_full Voltage sags and interruptions in a distribution system
title_fullStr Voltage sags and interruptions in a distribution system
title_full_unstemmed Voltage sags and interruptions in a distribution system
title_sort voltage sags and interruptions in a distribution system
publisher Universiti Malaysia Perlis
publishDate 2009
url http://dspace.unimap.edu.my/xmlui/handle/123456789/4267
_version_ 1643788097024950272
score 13.214268