Contactors and relays susceptibility to voltage sags

A contactor is electrically controlled switch used for switching a power circuit and activated by a control input which is a lower voltage or current than that which the contactor is switching. While a relay is an electrical switch that opens and closes under the control of another electrical cir...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Yazid Zaimuri
Other Authors: Mohd Rafi Adzman (Advisor)
Format: Learning Object
Language:English
Published: Universiti Malaysia Perlis 2009
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/4266
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-4266
record_format dspace
spelling my.unimap-42662009-01-28T08:58:58Z Contactors and relays susceptibility to voltage sags Mohd Yazid Zaimuri Mohd Rafi Adzman (Advisor) Voltage sag Power loss Power circuit -- Switching Electric power distribution Electric power system stability Electric power systems Electric power systems -- Quality control A contactor is electrically controlled switch used for switching a power circuit and activated by a control input which is a lower voltage or current than that which the contactor is switching. While a relay is an electrical switch that opens and closes under the control of another electrical circuit. In the original form, the switch is operated by an electromagnet to open or close one or many sets of contacts. Voltage sags are brief reductions in voltage from 0.1 to 0.9 p.u. in rms voltage at the power frequency for durations from 0.5 cycles (8ms) to 1 minute. Sags are the most common power disturbance. At a typical industrial site, it is not unusual to see several sags per year at the service entrance, and far more at equipment terminals. These two components are problematic network components from sag point of view. Both of these component control motors which keep complex industrial processes running. For an example, unintended tripping of one motor feeder may bring the whole process down or even worse, bring it to a state which difficult to restore back to a normal condition. In this project a Programmable software, Schaffner Profline 2100 EMC is used to generate the voltage sag. The equipment under test such as contactor and relay will be fed up with various depth and duration of sag. The characteristic of the equipment will be recorded. In other words, this research bring to the study of voltage sag tolerance level, the effects and causes to the two above equipments and all the characteristic when they operate in sags condition. Experiments done mostly result in various changes of characteristics to contactors and relays. Furthermore, the effects to the load such as blinking and flickering can be seen. The waveforms captured showed the effects clearly such as the spikes of the current and decrease in rms voltage. 2009-01-28T08:58:58Z 2009-01-28T08:58:58Z 2008-03 Learning Object http://hdl.handle.net/123456789/4266 en Universiti Malaysia Perlis School of Electrical Systems Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Voltage sag
Power loss
Power circuit -- Switching
Electric power distribution
Electric power system stability
Electric power systems
Electric power systems -- Quality control
spellingShingle Voltage sag
Power loss
Power circuit -- Switching
Electric power distribution
Electric power system stability
Electric power systems
Electric power systems -- Quality control
Mohd Yazid Zaimuri
Contactors and relays susceptibility to voltage sags
description A contactor is electrically controlled switch used for switching a power circuit and activated by a control input which is a lower voltage or current than that which the contactor is switching. While a relay is an electrical switch that opens and closes under the control of another electrical circuit. In the original form, the switch is operated by an electromagnet to open or close one or many sets of contacts. Voltage sags are brief reductions in voltage from 0.1 to 0.9 p.u. in rms voltage at the power frequency for durations from 0.5 cycles (8ms) to 1 minute. Sags are the most common power disturbance. At a typical industrial site, it is not unusual to see several sags per year at the service entrance, and far more at equipment terminals. These two components are problematic network components from sag point of view. Both of these component control motors which keep complex industrial processes running. For an example, unintended tripping of one motor feeder may bring the whole process down or even worse, bring it to a state which difficult to restore back to a normal condition. In this project a Programmable software, Schaffner Profline 2100 EMC is used to generate the voltage sag. The equipment under test such as contactor and relay will be fed up with various depth and duration of sag. The characteristic of the equipment will be recorded. In other words, this research bring to the study of voltage sag tolerance level, the effects and causes to the two above equipments and all the characteristic when they operate in sags condition. Experiments done mostly result in various changes of characteristics to contactors and relays. Furthermore, the effects to the load such as blinking and flickering can be seen. The waveforms captured showed the effects clearly such as the spikes of the current and decrease in rms voltage.
author2 Mohd Rafi Adzman (Advisor)
author_facet Mohd Rafi Adzman (Advisor)
Mohd Yazid Zaimuri
format Learning Object
author Mohd Yazid Zaimuri
author_sort Mohd Yazid Zaimuri
title Contactors and relays susceptibility to voltage sags
title_short Contactors and relays susceptibility to voltage sags
title_full Contactors and relays susceptibility to voltage sags
title_fullStr Contactors and relays susceptibility to voltage sags
title_full_unstemmed Contactors and relays susceptibility to voltage sags
title_sort contactors and relays susceptibility to voltage sags
publisher Universiti Malaysia Perlis
publishDate 2009
url http://dspace.unimap.edu.my/xmlui/handle/123456789/4266
_version_ 1643788096143097856
score 13.214268