Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component
Access is limited to UniMAP community.
Saved in:
Main Author: | |
---|---|
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2015
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40643 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-40643 |
---|---|
record_format |
dspace |
spelling |
my.unimap-406432016-02-04T05:04:00Z Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component Mohd Sukri, Zainal Abidin Reinforced concrete Wall panel Industrilized System (IBS) Rubber tyres Waste material Access is limited to UniMAP community. Reinforced concrete wall panel is a component used in the design and structure of buildings as space dividers or as load bearing walls, especially for application in the Industrilized System (IBS). The use of rubber tyres on the vehicle at this time showed a sharply increase from year to year, eventually contributed to the waste rubber tyres of the vehicle. The objectives of this study to determine the engineering properties based on existing standards and patterns of cracking of reinforced concrete wall panel when a waste rubber tyres replace the sand in concrete mix for IBS components. Percentages of crumb rubber tyres replace sand in the reinforced concrete wall panels are 0 % (control) and 2.5 %. The size reinforced concrete wall panel sample used is 750 mm x 750 mm x 125 mm for testing the compressive strength, cube size of 100 mm x 100 mm x 100 mm used for testing the fire resistance and compressive strength test after being burned. Collectively, the study shows that a mixture of 2.5 % rubber tyres replacing the sand in a reinforced concrete wall panels reached 56 % from 70 % of compressive strength equivalent to 3.0 MPa from 5.4 MPa sample that no replacement with rubber tyres and acceptable. In addition, the difference percentage compressive strength of sample for 2.5 % of rubber tyre was 13 % as 9.33 MPa from 10.84 MPa before the sample is burned. Only a little difference compressive strentgth between the sample before burn. The reinforced concrete wall panels are able to achieve the standards of fire resistance of 1 hour based on ASTM Standard 119. As conclusion, the use of 2.5 % of rubber tires in reinforced concrete wall panels are capable of achieving high standards and enhance its capabilities as reusable after burning to apply in Industrilized Building System(IBS) and reduce the sudden failure of structure by knowing the pattern of cracking that will be happen on reinforced concrete wall panel. 2015-12-11T07:36:18Z 2015-12-11T07:36:18Z 2014-06 Learning Object http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40643 en Universiti Malaysia Perlis (UniMAP) School of Environmental Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Reinforced concrete Wall panel Industrilized System (IBS) Rubber tyres Waste material |
spellingShingle |
Reinforced concrete Wall panel Industrilized System (IBS) Rubber tyres Waste material Mohd Sukri, Zainal Abidin Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component |
description |
Access is limited to UniMAP community. |
format |
Learning Object |
author |
Mohd Sukri, Zainal Abidin |
author_facet |
Mohd Sukri, Zainal Abidin |
author_sort |
Mohd Sukri, Zainal Abidin |
title |
Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component |
title_short |
Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component |
title_full |
Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component |
title_fullStr |
Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component |
title_full_unstemmed |
Performance of reinforced concrete wall panel with rubber tyre as sand replacement for IBS component |
title_sort |
performance of reinforced concrete wall panel with rubber tyre as sand replacement for ibs component |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2015 |
url |
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40643 |
_version_ |
1643799435051794432 |
score |
13.214268 |