Investigation the effect of zero seq harmonic in delta - wye transformer ramo error
Access is limited to UniMAP community.
Saved in:
Main Author: | |
---|---|
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2015
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40342 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-40342 |
---|---|
record_format |
dspace |
spelling |
my.unimap-403422015-07-24T08:23:03Z Investigation the effect of zero seq harmonic in delta - wye transformer ramo error Noor Izaida, Mahmad Idris Harmonics (Electric waves) Harmonic distortion Harmonic distortion analysis Power system Harmonic analysis Access is limited to UniMAP community. The research presented in this project concerns the sources of harmonic distortion (loads) and the interaction between those and the propagation of the distortion in the power system. Effects on the power system are also studied, e.g. additional losses, harmonic resonance and related financial costs to this. Further, mechanisms affecting the harmonic active power flow, in a certain point, are shown. The project is focus on how to measure the harmonic (zero sequence) on the load current. The increased losses due to harmonic distortion can cause excessive losses and hence abnormal temperature rise. The measurement of losses of three-phase transformers is important in particular for transformers feeding nonlinear loads. 2015-07-24T08:23:03Z 2015-07-24T08:23:03Z 2011 Learning Object http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40342 en Universiti Malaysia Perlis (UniMAP) School of Electrical Systems Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Harmonics (Electric waves) Harmonic distortion Harmonic distortion analysis Power system Harmonic analysis |
spellingShingle |
Harmonics (Electric waves) Harmonic distortion Harmonic distortion analysis Power system Harmonic analysis Noor Izaida, Mahmad Idris Investigation the effect of zero seq harmonic in delta - wye transformer ramo error |
description |
Access is limited to UniMAP community. |
format |
Learning Object |
author |
Noor Izaida, Mahmad Idris |
author_facet |
Noor Izaida, Mahmad Idris |
author_sort |
Noor Izaida, Mahmad Idris |
title |
Investigation the effect of zero seq harmonic in delta - wye transformer ramo error |
title_short |
Investigation the effect of zero seq harmonic in delta - wye transformer ramo error |
title_full |
Investigation the effect of zero seq harmonic in delta - wye transformer ramo error |
title_fullStr |
Investigation the effect of zero seq harmonic in delta - wye transformer ramo error |
title_full_unstemmed |
Investigation the effect of zero seq harmonic in delta - wye transformer ramo error |
title_sort |
investigation the effect of zero seq harmonic in delta - wye transformer ramo error |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2015 |
url |
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/40342 |
_version_ |
1643799339908202496 |
score |
13.222552 |