The use of air freshener in the premises of UniMAP and their potential health effect on human

Access is limited to UniMAP community.

Saved in:
Bibliographic Details
Main Author: Muhammad Khalid, Mohd. Kamarudin
Other Authors: Dr. Nasrul Hamidin
Format: Working Paper
Language:English
Published: Universiti Malaysia Perlis (UniMAP) 2014
Subjects:
Online Access:http://dspace.unimap.edu.my:80/dspace/handle/123456789/37103
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-37103
record_format dspace
spelling my.unimap-371032014-09-12T03:42:00Z The use of air freshener in the premises of UniMAP and their potential health effect on human Muhammad Khalid, Mohd. Kamarudin Dr. Nasrul Hamidin Air fresheners Health risk Chemical hazardours Indoor environment Access is limited to UniMAP community. A wide range of fragranced consumer products such as air fresheners, laundry supplies, personal care products, and cleaners are widely used in homes, businesses, institutions, and public places containing chemicals that fit the definition of hazardous or toxic. Of all the products in the indoor area, clean-smelling air fresheners seem to pose adverse health risk since humans spent most of their time in indoor environment. Data on levels of hazardous chemicals being released by the air freshener in developing countries, including Malaysia, are lacking. The present work deals with the estimation of target three types of chemicals 3 different location take as indoor area and 1 location as outdoor area where all the sampling works are conducted at School of Environmental Engineering. Toxic Gas Probe (TG-502) was used to measured the exposure level of naphthalene, chlorobenzene and o-dichlorobenzene (oDCB). The monitoring was carried out during working hours in the premises with no specific time were defined, during January 2011 to Mac 2011. In this study, the concentration of naphthalene, chlorobenzene and oDCB in office, room and toilet ranging between 30 μg/m³ to 163 μg/m³, 65 μg/m³ to 318 μg/m³, 66 μg/m³ to 241 μg/m³ respectively. On the other hand, the outdoor concentration for naphthalene, chlorobenzene and oDCB ranging between 10 μg/m³ to 52 μg/m³, 11 μg/m³ to 29 μg/m³, 11 μg/m³ to 19 μg/m³ respectively. This result indicated that the source of pollutants comes from inside of building particularly in area consist of air freshener. The health risk assessment using USEPA technique suggested that the workers are at high risk of having adverse health effect associated with the exposure level. 2014-09-12T03:42:00Z 2014-09-12T03:42:00Z 2011-05 Working Paper http://dspace.unimap.edu.my:80/dspace/handle/123456789/37103 en Universiti Malaysia Perlis (UniMAP) School of Environmental Engineering
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Air fresheners
Health risk
Chemical hazardours
Indoor environment
spellingShingle Air fresheners
Health risk
Chemical hazardours
Indoor environment
Muhammad Khalid, Mohd. Kamarudin
The use of air freshener in the premises of UniMAP and their potential health effect on human
description Access is limited to UniMAP community.
author2 Dr. Nasrul Hamidin
author_facet Dr. Nasrul Hamidin
Muhammad Khalid, Mohd. Kamarudin
format Working Paper
author Muhammad Khalid, Mohd. Kamarudin
author_sort Muhammad Khalid, Mohd. Kamarudin
title The use of air freshener in the premises of UniMAP and their potential health effect on human
title_short The use of air freshener in the premises of UniMAP and their potential health effect on human
title_full The use of air freshener in the premises of UniMAP and their potential health effect on human
title_fullStr The use of air freshener in the premises of UniMAP and their potential health effect on human
title_full_unstemmed The use of air freshener in the premises of UniMAP and their potential health effect on human
title_sort use of air freshener in the premises of unimap and their potential health effect on human
publisher Universiti Malaysia Perlis (UniMAP)
publishDate 2014
url http://dspace.unimap.edu.my:80/dspace/handle/123456789/37103
_version_ 1643798244735582208
score 13.214268