Upper extremity vein graft monitoring device after surgery procedure: a preliminary study

Link to publisher's homepage at http://www.ttp.net/

Saved in:
Bibliographic Details
Main Authors: Lee, Hoi Leong, Shahriman, Abu Bakar, Dr., Siti Khadijah, Za'aba, Dr., Wan Khairunizam, Wan Ahmad, Dr., Sharifah Roohi, Syed Waseem Ahmad, Zuradzman, Mohamad Razlan, Dr.
Other Authors: hoileong89@gmail.com
Format: Article
Language:English
Published: Trans Tech Publications 2014
Subjects:
Online Access:http://dspace.unimap.edu.my:80/dspace/handle/123456789/35410
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-35410
record_format dspace
spelling my.unimap-354102014-08-25T00:59:44Z Upper extremity vein graft monitoring device after surgery procedure: a preliminary study Lee, Hoi Leong Shahriman, Abu Bakar, Dr. Siti Khadijah, Za'aba, Dr. Wan Khairunizam, Wan Ahmad, Dr. Sharifah Roohi, Syed Waseem Ahmad Zuradzman, Mohamad Razlan, Dr. hoileong89@gmail.com shahriman@unimap.edu.my khadijah@unimap.edu.my khairunizam@unimap.edu.my roohi@medic.upm.edu.my zuradzman@unimap.edu.my. Electrical bioimpedance Impedance plethysmography Monitoring Upper extremity Vein graft Link to publisher's homepage at http://www.ttp.net/ In most cases, surgical vein bypass or interposition vein grafting was used in both primary management of crush-avulsion amputations and on intervention for rehabilitating the patency of occluded arteries via microvascular surgery. However, surgical revascularization has significant shortcomings, principal among which is the high rate of accelerated thrombosis that develops in arterialised vein graft which renders the vein graft susceptible to acute occlusion and eventually give rise to graft failure. Evaluaion and detection of vein graft failure is essential as that will be the starting point for the clinician to make the diagnosis and safeguard patency of implanted vein graft which would otherwise fail. Unfortunately, most of the available diagnostic and monitoring tools available in the market are expensive, hence not all the hospital, private clinic and others medical centers that fully-equipped with these type of equipments. The objective of this study is to design and develop a low-cost and non-invasive vein graft monitoring prototype that able to provide high accuracy in predicting the vein graft patency and meanwhile providing the short-term monitoring on vein graft right after surgery procedure. Impedance plethysmography (IPG) was employed to measure pulsatile changes in longitudinal impedace to quantify arterial blood flow and pulsatile blood volume. Tetra-polar electrode measurement system was implemented by introduce a constant 1-mA AC current (I) at frequency of 100 kHz in the two outer electrodes. The voltage (V) is measured between the two inner electrodes, and the resulting impedance (Z) is calculated using Ohm’s Law. Arterial blood flow and pulsatile blood volume can then be estimated using impedance related volume conduction equation. By measuring the changes in electrical bioimpedance which can be used to derive important hemodynamic variables, it allows the postoperative graft surveillance and early detection atherosclerosis and thrombosis as well as estimate its severity that leads to the vein graft failure. 2014-06-12T04:32:08Z 2014-06-12T04:32:08Z 2014 Article Advanced Materials Research, vol. 995, 2014, pages 656-660 1022-6680 (Print) 1662-8985 (Online) http://www.scientific.net/AMR.925.656 http://dspace.unimap.edu.my:80/dspace/handle/123456789/35410 10.4028/www.scientific.net/AMR.925.656 en Trans Tech Publications
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Electrical bioimpedance
Impedance plethysmography
Monitoring
Upper extremity
Vein graft
spellingShingle Electrical bioimpedance
Impedance plethysmography
Monitoring
Upper extremity
Vein graft
Lee, Hoi Leong
Shahriman, Abu Bakar, Dr.
Siti Khadijah, Za'aba, Dr.
Wan Khairunizam, Wan Ahmad, Dr.
Sharifah Roohi, Syed Waseem Ahmad
Zuradzman, Mohamad Razlan, Dr.
Upper extremity vein graft monitoring device after surgery procedure: a preliminary study
description Link to publisher's homepage at http://www.ttp.net/
author2 hoileong89@gmail.com
author_facet hoileong89@gmail.com
Lee, Hoi Leong
Shahriman, Abu Bakar, Dr.
Siti Khadijah, Za'aba, Dr.
Wan Khairunizam, Wan Ahmad, Dr.
Sharifah Roohi, Syed Waseem Ahmad
Zuradzman, Mohamad Razlan, Dr.
format Article
author Lee, Hoi Leong
Shahriman, Abu Bakar, Dr.
Siti Khadijah, Za'aba, Dr.
Wan Khairunizam, Wan Ahmad, Dr.
Sharifah Roohi, Syed Waseem Ahmad
Zuradzman, Mohamad Razlan, Dr.
author_sort Lee, Hoi Leong
title Upper extremity vein graft monitoring device after surgery procedure: a preliminary study
title_short Upper extremity vein graft monitoring device after surgery procedure: a preliminary study
title_full Upper extremity vein graft monitoring device after surgery procedure: a preliminary study
title_fullStr Upper extremity vein graft monitoring device after surgery procedure: a preliminary study
title_full_unstemmed Upper extremity vein graft monitoring device after surgery procedure: a preliminary study
title_sort upper extremity vein graft monitoring device after surgery procedure: a preliminary study
publisher Trans Tech Publications
publishDate 2014
url http://dspace.unimap.edu.my:80/dspace/handle/123456789/35410
_version_ 1643797786859143168
score 13.214268