Development of cost effective ECG data acquisition system for clinical applications using LabVIEW

Proceeding of The Proceeding of the 10th International Colloquium on Signal Processing & Its Applications (CSPA 2014) at Kuala Lumpur, Malaysia on 7 March 2014 until 9 March 2014. Link to publisher's homepage at http://ezproxy.unimap.edu.my:2080/Xplore/dynhome.jsp

Saved in:
Bibliographic Details
Main Authors: Murugappan, M., Dr., Thirumani, Reena, Mohammad Iqbal, Omar@Ye Htut, Assoc. Prof. Dr., Murugappan, Subbulakshmi
Other Authors: murugappan@unimap.edu.my
Format: Working Paper
Language:English
Published: IEEE Conference Publications 2014
Subjects:
ECG
Online Access:http://dspace.unimap.edu.my:80/dspace/handle/123456789/34514
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-34514
record_format dspace
spelling my.unimap-345142014-05-19T10:22:54Z Development of cost effective ECG data acquisition system for clinical applications using LabVIEW Murugappan, M., Dr. Thirumani, Reena Mohammad Iqbal, Omar@Ye Htut, Assoc. Prof. Dr. Murugappan, Subbulakshmi murugappan@unimap.edu.my iqbalomar@unimap.edu.my subbulakshmi@unimap.edu.my Data acquisition system ECG LabVIEW National Instruments (NI) Proceeding of The Proceeding of the 10th International Colloquium on Signal Processing & Its Applications (CSPA 2014) at Kuala Lumpur, Malaysia on 7 March 2014 until 9 March 2014. Link to publisher's homepage at http://ezproxy.unimap.edu.my:2080/Xplore/dynhome.jsp The main objective of this work is to develop a portable and cost effective data acquisition (DAQ) system for clinical applications. This DAQ consists of several modules such as power supply, analog to digital converter (ADC), amplifiers, isolators, filters and interfacing circuits. The complete data acquisition circuit has been developed using This system mainly aims to collect the ECG signals of frequency between 0.05 Hz and 113 Hz with a gain of 3113. This frequency information from the ECG signal is highly useful clinical applications such as SCA prediction, cardiovascular disease (CVD) detection, etc. ECG signals will be collected from the subjects using 3 leads system and given to DAQ for recording the ECG signal. The acquired signal through this DAQ will then be transferred to the Notebook through NI6008 data acquisition card. This DAQ interface is used to convert the input analog signal to digital signal output and to save the ECG data in the notebook using Labview software. This acquired signal from Labview software is used for further clinical investigation. We also developed a Graphical User Interface (GUI) in LabVIEW software to continuously monitor the ECG signal traces and to record the ECG data with higher precision. The morphology of the acquired ECG signal in the system is highly precise and useful for clinical diagnosis. Furthermore, this proposed system is used for developing sudden cardiac arrest (SCA) prediction in our university. 2014-05-19T10:20:16Z 2014-05-19T10:20:16Z 2014-03 Working Paper p. 100-105 978-1-4799-3090-6 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6805729&tag=1 http://dspace.unimap.edu.my:80/dspace/handle/123456789/34514 10.1109/CSPA.2014.6805729 en Proceeding of the 10th International Colloquium on Signal Processing & Its Applications (CSPA 2014); IEEE Conference Publications
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Data acquisition system
ECG
LabVIEW
National Instruments (NI)
spellingShingle Data acquisition system
ECG
LabVIEW
National Instruments (NI)
Murugappan, M., Dr.
Thirumani, Reena
Mohammad Iqbal, Omar@Ye Htut, Assoc. Prof. Dr.
Murugappan, Subbulakshmi
Development of cost effective ECG data acquisition system for clinical applications using LabVIEW
description Proceeding of The Proceeding of the 10th International Colloquium on Signal Processing & Its Applications (CSPA 2014) at Kuala Lumpur, Malaysia on 7 March 2014 until 9 March 2014. Link to publisher's homepage at http://ezproxy.unimap.edu.my:2080/Xplore/dynhome.jsp
author2 murugappan@unimap.edu.my
author_facet murugappan@unimap.edu.my
Murugappan, M., Dr.
Thirumani, Reena
Mohammad Iqbal, Omar@Ye Htut, Assoc. Prof. Dr.
Murugappan, Subbulakshmi
format Working Paper
author Murugappan, M., Dr.
Thirumani, Reena
Mohammad Iqbal, Omar@Ye Htut, Assoc. Prof. Dr.
Murugappan, Subbulakshmi
author_sort Murugappan, M., Dr.
title Development of cost effective ECG data acquisition system for clinical applications using LabVIEW
title_short Development of cost effective ECG data acquisition system for clinical applications using LabVIEW
title_full Development of cost effective ECG data acquisition system for clinical applications using LabVIEW
title_fullStr Development of cost effective ECG data acquisition system for clinical applications using LabVIEW
title_full_unstemmed Development of cost effective ECG data acquisition system for clinical applications using LabVIEW
title_sort development of cost effective ecg data acquisition system for clinical applications using labview
publisher IEEE Conference Publications
publishDate 2014
url http://dspace.unimap.edu.my:80/dspace/handle/123456789/34514
_version_ 1643797513483845632
score 13.214268