Effect of solution treatment on magnesium sacrificial anode
The main objective of this study is to determine the effect of solution treatment period on the corrosion behavior of magnesium anode. Commercial high potential magnesium anode was heat-treated at 3000C for 3, 6 and 9 hours in high temperature oven. After quenched, all samples were aged at 1500C for...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Learning Object |
Language: | English |
Published: |
Universiti Malaysia Perlis
2008
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/3269 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-3269 |
---|---|
record_format |
dspace |
spelling |
my.unimap-32692008-11-17T07:43:57Z Effect of solution treatment on magnesium sacrificial anode Norliawati Nor Azman Shaiful Rizam Shamsudin (Advisor) Magnesium anode Corrosions Corrosion and anti-corrosives Metal corrosion Corrosions -- Prevention The main objective of this study is to determine the effect of solution treatment period on the corrosion behavior of magnesium anode. Commercial high potential magnesium anode was heat-treated at 3000C for 3, 6 and 9 hours in high temperature oven. After quenched, all samples were aged at 1500C for 8 hours. Electrochemical testing such as open circuit potential, Tafel plot, potentiodynamic anodic polarization were carried out by Gambry potentiostat/ galvanostat equipment. It was found that as-received high potential magnesium anode exhibit high corrosion potential (-1680 mV vs SCE) and also high corrosion rate (4.148 x 103 mm/year). It was also found that by the increasing the solution treatment period, the corrosion rate was reduced. The appearance of needle like structure was found increases the corrosion rate of magnesium anode. 2008-11-17T07:43:57Z 2008-11-17T07:43:57Z 2008-04 Learning Object http://hdl.handle.net/123456789/3269 en Universiti Malaysia Perlis School of Materials Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Magnesium anode Corrosions Corrosion and anti-corrosives Metal corrosion Corrosions -- Prevention |
spellingShingle |
Magnesium anode Corrosions Corrosion and anti-corrosives Metal corrosion Corrosions -- Prevention Norliawati Nor Azman Effect of solution treatment on magnesium sacrificial anode |
description |
The main objective of this study is to determine the effect of solution treatment period on the corrosion behavior of magnesium anode. Commercial high potential magnesium anode was heat-treated at 3000C for 3, 6 and 9 hours in high temperature oven. After quenched, all samples were aged at 1500C for 8 hours. Electrochemical testing such as open circuit potential, Tafel plot, potentiodynamic anodic polarization were carried out by Gambry
potentiostat/ galvanostat equipment. It was found that as-received high potential magnesium anode exhibit high corrosion potential (-1680 mV vs SCE) and also high
corrosion rate (4.148 x 103 mm/year). It was also found that by the increasing the solution treatment period, the corrosion rate was reduced. The appearance of needle like structure was found increases the corrosion rate of magnesium anode. |
author2 |
Shaiful Rizam Shamsudin (Advisor) |
author_facet |
Shaiful Rizam Shamsudin (Advisor) Norliawati Nor Azman |
format |
Learning Object |
author |
Norliawati Nor Azman |
author_sort |
Norliawati Nor Azman |
title |
Effect of solution treatment on magnesium sacrificial anode |
title_short |
Effect of solution treatment on magnesium sacrificial anode |
title_full |
Effect of solution treatment on magnesium sacrificial anode |
title_fullStr |
Effect of solution treatment on magnesium sacrificial anode |
title_full_unstemmed |
Effect of solution treatment on magnesium sacrificial anode |