Application-specific multichannel EEG data acquisition system for portable biomedical application
Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis.
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Working Paper |
Language: | English |
Published: |
Malaysian Technical Universities Network (MTUN)
2013
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/27024 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-27024 |
---|---|
record_format |
dspace |
spelling |
my.unimap-270242015-07-14T02:52:38Z Application-specific multichannel EEG data acquisition system for portable biomedical application Paulraj, Murugesa Pandian, Dr. Abdul Hamid, Adom, Prof. Dr. Tung, Kai Xu Subramaniam, Kamalraj paul@unimap.edu.my EEG Input impedance CMRR Active filter EEG amplifier Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. This paper presents the design and construction of a low power application-specific EEG bio-potential multichannel amplifier with high common mode rejection ratio (CMRR) and high input impedance. The bio-potential amplifier designed was band-limited specifically (0-40Hz) to control the power-line noise interferences and intends to record event-related and evoked potentials of the somatosensory stimuli. The fabricated EEG bio-potential amplifier has a CMRR of 140 dB below 100 Hz with an input impedance of 300 MΩ. The designed EEG bio-potential amplifier circuit meets the required specification of low power consumption and high gain. The EEG bio-potential amplifier was tested on young healthy subjects and the results were compared to those obtained using commercially available EEG amplifiers. The observed results with the designed bio-potential amplifier are able to provide significant information for biomedical engineering research. 2013-07-23T12:49:49Z 2013-07-23T12:49:49Z 2012-11-20 Working Paper p. 67-70 http://hdl.handle.net/123456789/27024 en Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 Malaysian Technical Universities Network (MTUN) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
EEG Input impedance CMRR Active filter EEG amplifier |
spellingShingle |
EEG Input impedance CMRR Active filter EEG amplifier Paulraj, Murugesa Pandian, Dr. Abdul Hamid, Adom, Prof. Dr. Tung, Kai Xu Subramaniam, Kamalraj Application-specific multichannel EEG data acquisition system for portable biomedical application |
description |
Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. |
author2 |
paul@unimap.edu.my |
author_facet |
paul@unimap.edu.my Paulraj, Murugesa Pandian, Dr. Abdul Hamid, Adom, Prof. Dr. Tung, Kai Xu Subramaniam, Kamalraj |
format |
Working Paper |
author |
Paulraj, Murugesa Pandian, Dr. Abdul Hamid, Adom, Prof. Dr. Tung, Kai Xu Subramaniam, Kamalraj |
author_sort |
Paulraj, Murugesa Pandian, Dr. |
title |
Application-specific multichannel EEG data acquisition system for portable biomedical application |
title_short |
Application-specific multichannel EEG data acquisition system for portable biomedical application |
title_full |
Application-specific multichannel EEG data acquisition system for portable biomedical application |
title_fullStr |
Application-specific multichannel EEG data acquisition system for portable biomedical application |
title_full_unstemmed |
Application-specific multichannel EEG data acquisition system for portable biomedical application |
title_sort |
application-specific multichannel eeg data acquisition system for portable biomedical application |
publisher |
Malaysian Technical Universities Network (MTUN) |
publishDate |
2013 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/27024 |
_version_ |
1643795018514694144 |
score |
13.214268 |