Application-specific multichannel EEG data acquisition system for portable biomedical application

Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis.

Saved in:
Bibliographic Details
Main Authors: Paulraj, Murugesa Pandian, Dr., Abdul Hamid, Adom, Prof. Dr., Tung, Kai Xu, Subramaniam, Kamalraj
Other Authors: paul@unimap.edu.my
Format: Working Paper
Language:English
Published: Malaysian Technical Universities Network (MTUN) 2013
Subjects:
EEG
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/27024
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-27024
record_format dspace
spelling my.unimap-270242015-07-14T02:52:38Z Application-specific multichannel EEG data acquisition system for portable biomedical application Paulraj, Murugesa Pandian, Dr. Abdul Hamid, Adom, Prof. Dr. Tung, Kai Xu Subramaniam, Kamalraj paul@unimap.edu.my EEG Input impedance CMRR Active filter EEG amplifier Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. This paper presents the design and construction of a low power application-specific EEG bio-potential multichannel amplifier with high common mode rejection ratio (CMRR) and high input impedance. The bio-potential amplifier designed was band-limited specifically (0-40Hz) to control the power-line noise interferences and intends to record event-related and evoked potentials of the somatosensory stimuli. The fabricated EEG bio-potential amplifier has a CMRR of 140 dB below 100 Hz with an input impedance of 300 MΩ. The designed EEG bio-potential amplifier circuit meets the required specification of low power consumption and high gain. The EEG bio-potential amplifier was tested on young healthy subjects and the results were compared to those obtained using commercially available EEG amplifiers. The observed results with the designed bio-potential amplifier are able to provide significant information for biomedical engineering research. 2013-07-23T12:49:49Z 2013-07-23T12:49:49Z 2012-11-20 Working Paper p. 67-70 http://hdl.handle.net/123456789/27024 en Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 Malaysian Technical Universities Network (MTUN)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic EEG
Input impedance
CMRR
Active filter
EEG amplifier
spellingShingle EEG
Input impedance
CMRR
Active filter
EEG amplifier
Paulraj, Murugesa Pandian, Dr.
Abdul Hamid, Adom, Prof. Dr.
Tung, Kai Xu
Subramaniam, Kamalraj
Application-specific multichannel EEG data acquisition system for portable biomedical application
description Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis.
author2 paul@unimap.edu.my
author_facet paul@unimap.edu.my
Paulraj, Murugesa Pandian, Dr.
Abdul Hamid, Adom, Prof. Dr.
Tung, Kai Xu
Subramaniam, Kamalraj
format Working Paper
author Paulraj, Murugesa Pandian, Dr.
Abdul Hamid, Adom, Prof. Dr.
Tung, Kai Xu
Subramaniam, Kamalraj
author_sort Paulraj, Murugesa Pandian, Dr.
title Application-specific multichannel EEG data acquisition system for portable biomedical application
title_short Application-specific multichannel EEG data acquisition system for portable biomedical application
title_full Application-specific multichannel EEG data acquisition system for portable biomedical application
title_fullStr Application-specific multichannel EEG data acquisition system for portable biomedical application
title_full_unstemmed Application-specific multichannel EEG data acquisition system for portable biomedical application
title_sort application-specific multichannel eeg data acquisition system for portable biomedical application
publisher Malaysian Technical Universities Network (MTUN)
publishDate 2013
url http://dspace.unimap.edu.my/xmlui/handle/123456789/27024
_version_ 1643795018514694144
score 13.214268