Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition
Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis.
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Working Paper |
Language: | English |
Published: |
Malaysian Technical Universities Network (MTUN)
2013
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/26584 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-26584 |
---|---|
record_format |
dspace |
spelling |
my.unimap-265842013-07-12T05:05:08Z Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition Nur Zawani, Saharuddin Junainah, Leman Imran, Sutan Chairul Mohd Faizuhar, Razali nurzawani@utem.edu.my Lightning overvoltage Lightning- strike current Phase conductor Shielding failure Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. Lightning overvoltage is the major cause of the transmission line interruption in Malaysia. It is the main reason that endangers the safety and reliability of transmission line system. The phenomenon is a dominant factor considered in designing substations and transmission-line insulation, therefore its investigation is important. This work modelled a 132 kV overhead transmission line for shielding failure pattern recognition by using ATP-EMTP software, as they are vital to the evaluation of lightning performance. The modelled transmission-line is divided into few parts: wires (shield wires and phase conductors), towers, cross-arms, insulator strings, tower-surge impedance and tower-footing resistance. The developed model is simulated with four different magnitudes of lightning-strike current on each phase conductor in order to investigate the shielding failure voltage pattern across the line insulation in the transmission line system. When the lightning- strike current is injected from upper phase to lower phase conductor, the magnitude of the maximum induced voltage across the insulator string at those phases has been decreased. On the other hand, as the magnitude of the lightning- strike current has been increased, the magnitude of the maximum induced voltage across the insulator string at each phase will be increased. Flashover occurs when the voltage induced across the insulator string at each phase is equal or exceeds the CFO voltage. These analyses have been done based on the waveforms obtained from the simulations on developed model. 2013-07-12T05:05:08Z 2013-07-12T05:05:08Z 2012-11-20 Working Paper p. 59-65 http://hdl.handle.net/123456789/26584 en Proceeding of the Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 Malaysian Technical Universities Network (MTUN) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Lightning overvoltage Lightning- strike current Phase conductor Shielding failure |
spellingShingle |
Lightning overvoltage Lightning- strike current Phase conductor Shielding failure Nur Zawani, Saharuddin Junainah, Leman Imran, Sutan Chairul Mohd Faizuhar, Razali Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition |
description |
Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. |
author2 |
nurzawani@utem.edu.my |
author_facet |
nurzawani@utem.edu.my Nur Zawani, Saharuddin Junainah, Leman Imran, Sutan Chairul Mohd Faizuhar, Razali |
format |
Working Paper |
author |
Nur Zawani, Saharuddin Junainah, Leman Imran, Sutan Chairul Mohd Faizuhar, Razali |
author_sort |
Nur Zawani, Saharuddin |
title |
Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition |
title_short |
Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition |
title_full |
Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition |
title_fullStr |
Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition |
title_full_unstemmed |
Modelling of 132kV overhead transmission lines by using ATP/ EMTP for shielding failure pattern recognition |
title_sort |
modelling of 132kv overhead transmission lines by using atp/ emtp for shielding failure pattern recognition |
publisher |
Malaysian Technical Universities Network (MTUN) |
publishDate |
2013 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/26584 |
_version_ |
1643794994328240128 |
score |
13.214268 |