Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination

Organized by Universiti Malaysia Perlis (UniMAP), 15th - 16th March 2008 at Putra Brasmana Hotel, Perlis.

Saved in:
Bibliographic Details
Main Authors: Ismail, Daut, Dina Maizana, Maiz Ahmad, Shuhaimi, Zakaria, S. Uthman, Soib, Taib
Format: Working Paper
Language:English
Published: Universiti Malaysia Perlis (UniMAP) 2008
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/2431
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-2431
record_format dspace
spelling my.unimap-24312014-05-05T06:39:03Z Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination Ismail, Daut Dina Maizana, Maiz Ahmad Shuhaimi, Zakaria S. Uthman Soib, Taib Transformer core Flux distribution Power loss Transformers Organized by Universiti Malaysia Perlis (UniMAP), 15th - 16th March 2008 at Putra Brasmana Hotel, Perlis. This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building factor, the third harmonic of voltage and flux leakages. The power loss and flux distribution have been measured using no load test in two types of model setting of core built from the same size and type of M5 (CGO) grades material of laminations. And the loss of the transformer core with regular stack is 6.55% better than the loss of the transformer core with irregular stack at 1.7T, 50 Hz. The flux leakage at the corner joint in the core with regular stack of lamination is lower than the two of the transformer core, over the whole flux density range. The total harmonic distortation of flux is smaller in the transformer core with regular stack of lamination and larger in the transformer core with irregular stack of lamination. Using regular stack of lamination in transformer core is more efficient than two types of stack of transformer core lamination. 2008-10-18T06:09:57Z 2008-10-18T06:09:57Z 2008-03-10 Working Paper http://hdl.handle.net/123456789/2431 en Malaysian Universities Conferences on Engineering and Technology (MUCET2008) Universiti Malaysia Perlis (UniMAP)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Transformer core
Flux distribution
Power loss
Transformers
spellingShingle Transformer core
Flux distribution
Power loss
Transformers
Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
S. Uthman
Soib, Taib
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
description Organized by Universiti Malaysia Perlis (UniMAP), 15th - 16th March 2008 at Putra Brasmana Hotel, Perlis.
format Working Paper
author Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
S. Uthman
Soib, Taib
author_facet Ismail, Daut
Dina Maizana, Maiz Ahmad
Shuhaimi, Zakaria
S. Uthman
Soib, Taib
author_sort Ismail, Daut
title Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
title_short Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
title_full Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
title_fullStr Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
title_full_unstemmed Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
title_sort comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kva assembled with regular and irregular stack of transformer core lamination
publisher Universiti Malaysia Perlis (UniMAP)
publishDate 2008
url http://dspace.unimap.edu.my/xmlui/handle/123456789/2431
_version_ 1643787526407716864
score 13.160551