Contribution factors to transformer failure under no load condition and mitigation action
Organized by Kolej Universiti Teknologi Tun Hussein Onn (KUiTTHO), 19th - 20th December 2006 at Batu Pahat, Johor.
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Working Paper |
Language: | English |
Published: |
Kolej Universiti Teknologi Tun Hussein Onn (KUiTTHO)
2008
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/2356 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-2356 |
---|---|
record_format |
dspace |
spelling |
my.unimap-23562014-05-05T06:34:53Z Contribution factors to transformer failure under no load condition and mitigation action Ismail, Daut Shahanom, Uthman Young Zaidey Dina Maizana, Maiz Ahmad Moses, Anthony J. Transformers Electric transformers Overvoltage Lightning Electric power systems -- Protection Organized by Kolej Universiti Teknologi Tun Hussein Onn (KUiTTHO), 19th - 20th December 2006 at Batu Pahat, Johor. The study on transformer failure was carried out on commercial 1500 kVA 33/11 kV in TNB network distribution systems. The damage experienced by the transformer under study was suspected due to the transient surge overvoltage phenomenon activities. The source of surge has been investigated and analyzed from the recorded lighting data captured from the substation circuit. This paper presents the holistic approach of possible causes on the surge transient. Internal and external overvoltage sources are mentioned in detail to described the failure incident. Recommendation to prevent such failure in the future and to improve transformer performance are also discussed. 2008-10-09T07:42:46Z 2008-10-09T07:42:46Z 2006-12-20 Working Paper pp. 206-215 http://hdl.handle.net/123456789/2356 en Malaysian Technical Universities Conference on Engineering and Technology (MUCET 2006) Kolej Universiti Teknologi Tun Hussein Onn (KUiTTHO) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Transformers Electric transformers Overvoltage Lightning Electric power systems -- Protection |
spellingShingle |
Transformers Electric transformers Overvoltage Lightning Electric power systems -- Protection Ismail, Daut Shahanom, Uthman Young Zaidey Dina Maizana, Maiz Ahmad Moses, Anthony J. Contribution factors to transformer failure under no load condition and mitigation action |
description |
Organized by Kolej Universiti Teknologi Tun Hussein Onn (KUiTTHO), 19th - 20th December 2006 at Batu Pahat, Johor. |
format |
Working Paper |
author |
Ismail, Daut Shahanom, Uthman Young Zaidey Dina Maizana, Maiz Ahmad Moses, Anthony J. |
author_facet |
Ismail, Daut Shahanom, Uthman Young Zaidey Dina Maizana, Maiz Ahmad Moses, Anthony J. |
author_sort |
Ismail, Daut |
title |
Contribution factors to transformer failure under no load condition and mitigation action |
title_short |
Contribution factors to transformer failure under no load condition and mitigation action |
title_full |
Contribution factors to transformer failure under no load condition and mitigation action |
title_fullStr |
Contribution factors to transformer failure under no load condition and mitigation action |
title_full_unstemmed |
Contribution factors to transformer failure under no load condition and mitigation action |
title_sort |
contribution factors to transformer failure under no load condition and mitigation action |
publisher |
Kolej Universiti Teknologi Tun Hussein Onn (KUiTTHO) |
publishDate |
2008 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/2356 |
_version_ |
1643787586874900480 |
score |
13.222552 |