A method for ground fault distance computation in unearthed medium voltage distribution network
Link to publisher's homepage at http://www.praiseworthyprize.it/
Saved in:
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
Praise Worthy Prize S.r.l.
2013
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/22908 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-22908 |
---|---|
record_format |
dspace |
spelling |
my.unimap-229082013-01-09T01:39:08Z A method for ground fault distance computation in unearthed medium voltage distribution network Mohd Rafi, Adzman Lehtonen, Matti mohdrafi@unimap.edu.my Charge transient Fault location Impedance matrix Unearthed network Link to publisher's homepage at http://www.praiseworthyprize.it/ In networks with unearthed or compensated neutral, earth fault signals consist of different frequency components, which result from charging and discharging of the network capacitances. The charge transient which usually is of higher amplitude and lower frequency than the discharge transient is most suitable for fault location. This paper discusses a method for estimating a single phase to ground fault location in radially operated unearthed distribution network. The proposed method is based on correlation of undamped charge transient frequency with the fault distance. The undamped complex frequency is defined from the development of single phase to ground fault bus impedance matrix of the circuit network in complex frequency domain. The accuracy of the method was tested using a simulation model and the network example with overhead lines. The analysis was performed using the EMTP-ATP software. 2013-01-09T01:39:08Z 2013-01-09T01:39:08Z 2012 Article International Review on Modelling and Simulations, vol. 5 (4), 2012, pages 1765-1772 1974-9821 http://www.praiseworthyprize.it/public/SUBSCRIBERS/IREMOS.html http://hdl.handle.net/123456789/22908 en Praise Worthy Prize S.r.l. |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Charge transient Fault location Impedance matrix Unearthed network |
spellingShingle |
Charge transient Fault location Impedance matrix Unearthed network Mohd Rafi, Adzman Lehtonen, Matti A method for ground fault distance computation in unearthed medium voltage distribution network |
description |
Link to publisher's homepage at http://www.praiseworthyprize.it/ |
author2 |
mohdrafi@unimap.edu.my |
author_facet |
mohdrafi@unimap.edu.my Mohd Rafi, Adzman Lehtonen, Matti |
format |
Article |
author |
Mohd Rafi, Adzman Lehtonen, Matti |
author_sort |
Mohd Rafi, Adzman |
title |
A method for ground fault distance computation in unearthed medium voltage distribution network |
title_short |
A method for ground fault distance computation in unearthed medium voltage distribution network |
title_full |
A method for ground fault distance computation in unearthed medium voltage distribution network |
title_fullStr |
A method for ground fault distance computation in unearthed medium voltage distribution network |
title_full_unstemmed |
A method for ground fault distance computation in unearthed medium voltage distribution network |
title_sort |
method for ground fault distance computation in unearthed medium voltage distribution network |
publisher |
Praise Worthy Prize S.r.l. |
publishDate |
2013 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/22908 |
_version_ |
1643793833288269824 |
score |
13.214268 |