Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor
Link to publisher's homepage at http://ieeexplore.ieee.org/
Saved in:
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Working Paper |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers (IEEE)
2012
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/21403 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-21403 |
---|---|
record_format |
dspace |
spelling |
my.unimap-214032012-10-18T07:52:03Z Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor Chaichanyut, M. Tungjitkusolmun, Supan, Dr. kcmontre@kmitl.ac.th ktsupan@kmitl.ac.th Component Microwave Ablation Ring slot antennas Liver tumor Link to publisher's homepage at http://ieeexplore.ieee.org/ In recent years, various types of applications of electromagnetic techniques to microwave thermal therapies have been developed. The authors have been studying the coaxial ringslot antenna. We analyses the temperature distribution pattern and lesion size on hepatic cancer at frequency of 2.45GHz. We set the potential difference between the inner and outer conductors were 50V and set duration time for microwave ablation in the range 60s, 100s, 200s and 300s. From the simulation results of our previous studies, Numerical electromagnetic and thermal simulations are used to optimize the antenna design and predict heating patterns. Numerical results show the temperature distributions that all time had similar characteristics but, there are differently at the lesion size. When we set the ablation time was 300s the lesion size was larger, with a lesion width approximately 17 mm, compared to 10 mm for set the ablation time was 60s. If we considered the lesion volumes at the ablation time was 300s this case can be induced the highest temperature in cancer tissue and maximum ablation cancer tissue (3.74cm3). In addition, we also set the boundary conditions on temperature control mode which maximum temperature control within hepatic cancer at 96°C, duration time at 300s. From the simulation results, the volume of lesion size was 0.98 cm3, lesion width and depth approximately 11mm, 19mm. respectively. 2012-10-18T07:52:03Z 2012-10-18T07:52:03Z 2012-02-27 Working Paper p. 450-453 978-145771989-9 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?tp=&arnumber=6179056 http://hdl.handle.net/123456789/21403 en Proceedings of the International Conference on Biomedical Engineering (ICoBE 2012) Institute of Electrical and Electronics Engineers (IEEE) |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Component Microwave Ablation Ring slot antennas Liver tumor |
spellingShingle |
Component Microwave Ablation Ring slot antennas Liver tumor Chaichanyut, M. Tungjitkusolmun, Supan, Dr. Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor |
description |
Link to publisher's homepage at http://ieeexplore.ieee.org/ |
author2 |
kcmontre@kmitl.ac.th |
author_facet |
kcmontre@kmitl.ac.th Chaichanyut, M. Tungjitkusolmun, Supan, Dr. |
format |
Working Paper |
author |
Chaichanyut, M. Tungjitkusolmun, Supan, Dr. |
author_sort |
Chaichanyut, M. |
title |
Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor |
title_short |
Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor |
title_full |
Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor |
title_fullStr |
Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor |
title_full_unstemmed |
Thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor |
title_sort |
thermal conduction and perfusion of ring-slot microwave antenna for treatment liver tumor |
publisher |
Institute of Electrical and Electronics Engineers (IEEE) |
publishDate |
2012 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/21403 |
_version_ |
1643793369298632704 |
score |
13.214268 |