Investigation of power factor on harmonic effect due to types of voltage source

International Postgraduate Conference On Engineering (IPCE 2010), 16th - 17th October 2010 organized by Centre for Graduate Studies, Universiti Malaysia Perlis (UniMAP) at School of Mechatronic Engineering, Pauh Putra Campus, Arau, Perlis, Malaysia.

Saved in:
Bibliographic Details
Main Authors: Risnidar Chan Bahaudin, Ir., Ismail, Daut, Prof. Dr., Syafruddin, Hassan, M. I., Yussof, Rosnazri, Ali, Dina Maizana, Maiz Ahmad, Indra, Nisja, Masykur
Other Authors: risnidar@unimap.edu.my
Format: Working Paper
Language:English
Published: Universiti Malaysia Perlis (UniMAP) 2012
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/21224
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-21224
record_format dspace
spelling my.unimap-212242017-11-29T08:36:38Z Investigation of power factor on harmonic effect due to types of voltage source Risnidar Chan Bahaudin, Ir. Ismail, Daut, Prof. Dr. Syafruddin, Hassan M. I., Yussof Rosnazri, Ali Dina Maizana, Maiz Ahmad Indra, Nisja Masykur risnidar@unimap.edu.my Type of voltage source Power factor Energy losses cost Harmonic Total Harmonic Distortion (THD) International Postgraduate Conference On Engineering (IPCE 2010), 16th - 17th October 2010 organized by Centre for Graduate Studies, Universiti Malaysia Perlis (UniMAP) at School of Mechatronic Engineering, Pauh Putra Campus, Arau, Perlis, Malaysia. This paper discussed about power factor on harmonic effect due to types of voltage source. Usually, the voltage source is sinusoidal. But in actually, the condition of the load is has voltage sources through the elements where the output voltage of element as input to load is did not pure sinusoidal, for example at PCC between transformer and linear load and nonlinear load. The research has done with Schhafner Power Quality Analyzer. The research was focused to power factor (p.f.), THD, and harmonic energy losses cost from measurement where load is Induction motor and ASD. As voltage source in this research are sine wave and combinations of 3rd, 5th and 7th harmonic order like harmonic 313, and harmonic 357. 2012-10-05T04:05:00Z 2012-10-05T04:05:00Z 2010-10-16 Working Paper 978-967-5760-03-7 http://hdl.handle.net/123456789/21224 en Proceedings of the International Postgraduate Conference on Engineering (IPCE 2010) Universiti Malaysia Perlis (UniMAP) Centre for Graduate Studies
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Type of voltage source
Power factor
Energy losses cost
Harmonic
Total Harmonic Distortion (THD)
spellingShingle Type of voltage source
Power factor
Energy losses cost
Harmonic
Total Harmonic Distortion (THD)
Risnidar Chan Bahaudin, Ir.
Ismail, Daut, Prof. Dr.
Syafruddin, Hassan
M. I., Yussof
Rosnazri, Ali
Dina Maizana, Maiz Ahmad
Indra, Nisja
Masykur
Investigation of power factor on harmonic effect due to types of voltage source
description International Postgraduate Conference On Engineering (IPCE 2010), 16th - 17th October 2010 organized by Centre for Graduate Studies, Universiti Malaysia Perlis (UniMAP) at School of Mechatronic Engineering, Pauh Putra Campus, Arau, Perlis, Malaysia.
author2 risnidar@unimap.edu.my
author_facet risnidar@unimap.edu.my
Risnidar Chan Bahaudin, Ir.
Ismail, Daut, Prof. Dr.
Syafruddin, Hassan
M. I., Yussof
Rosnazri, Ali
Dina Maizana, Maiz Ahmad
Indra, Nisja
Masykur
format Working Paper
author Risnidar Chan Bahaudin, Ir.
Ismail, Daut, Prof. Dr.
Syafruddin, Hassan
M. I., Yussof
Rosnazri, Ali
Dina Maizana, Maiz Ahmad
Indra, Nisja
Masykur
author_sort Risnidar Chan Bahaudin, Ir.
title Investigation of power factor on harmonic effect due to types of voltage source
title_short Investigation of power factor on harmonic effect due to types of voltage source
title_full Investigation of power factor on harmonic effect due to types of voltage source
title_fullStr Investigation of power factor on harmonic effect due to types of voltage source
title_full_unstemmed Investigation of power factor on harmonic effect due to types of voltage source
title_sort investigation of power factor on harmonic effect due to types of voltage source
publisher Universiti Malaysia Perlis (UniMAP)
publishDate 2012
url http://dspace.unimap.edu.my/xmlui/handle/123456789/21224
_version_ 1643802724427366400
score 13.214268