Voltage sag and the sensitive load

Organized by Universiti Malaysia Sarawak (UNIMAS), 27th - 28th December 2007 at Kuching, Sarawak, Malaysia.

Saved in:
Bibliographic Details
Main Authors: Ismail, Daut, Che Mat Hadzer, Mahmud, Surya, Hardi, Risnidar Chan, Bahaudin, Saedah, Siraj, Nor Haidar, Hashim
Format: Working Paper
Language:English
Published: Universiti Malaysia Sarawak (UNIMAS) 2008
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/2081
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-2081
record_format dspace
spelling my.unimap-20812017-11-29T08:48:32Z Voltage sag and the sensitive load Ismail, Daut Che Mat Hadzer, Mahmud Surya, Hardi Risnidar Chan, Bahaudin Saedah, Siraj Nor Haidar, Hashim Voltage sag Clearing time Sag severity Sensitive load Electromotive force Electric power systems Electric power systems -- Electric losses Electric utilities -- Quality control Organized by Universiti Malaysia Sarawak (UNIMAS), 27th - 28th December 2007 at Kuching, Sarawak, Malaysia. Voltage sag is the important factor in power quality problem faced by many industrial consumers. The most frequently reported among various types of power quality disturbance are voltages sags. The disturbance will cause the sensitive load/equipment (adjustable speed drive, contactor starter in motor, etc. to drop out. The main source of voltage sags are faults on the utility system and motor starting. Voltage sag caused by faults are generally more severe than those caused by starting. Voltage sag is normally characterized by a magnitude and duration. The load sensitivity is generally determined by the both values. The sag magnitude is depending on fault location and fault type. The sag duration depends on the clearing time the protective device used. This paper discusses estimation of voltage sag cause by fault in distribution system that supplied to the sensitive load and sag duration can be controlled using protective device. The result shows that the faults on the adjacent sensitive load are more severe and sensitive load protected by protective device characteristics with longer operating time will most likely to drop out. 2008-09-10T04:09:58Z 2008-09-10T04:09:58Z 2007-12-28 Working Paper http://hdl.handle.net/123456789/2081 en 1st Engineering Conference on Energy & Environment (EnCon 2007) Universiti Malaysia Sarawak (UNIMAS)
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Voltage sag
Clearing time
Sag severity
Sensitive load
Electromotive force
Electric power systems
Electric power systems -- Electric losses
Electric utilities -- Quality control
spellingShingle Voltage sag
Clearing time
Sag severity
Sensitive load
Electromotive force
Electric power systems
Electric power systems -- Electric losses
Electric utilities -- Quality control
Ismail, Daut
Che Mat Hadzer, Mahmud
Surya, Hardi
Risnidar Chan, Bahaudin
Saedah, Siraj
Nor Haidar, Hashim
Voltage sag and the sensitive load
description Organized by Universiti Malaysia Sarawak (UNIMAS), 27th - 28th December 2007 at Kuching, Sarawak, Malaysia.
format Working Paper
author Ismail, Daut
Che Mat Hadzer, Mahmud
Surya, Hardi
Risnidar Chan, Bahaudin
Saedah, Siraj
Nor Haidar, Hashim
author_facet Ismail, Daut
Che Mat Hadzer, Mahmud
Surya, Hardi
Risnidar Chan, Bahaudin
Saedah, Siraj
Nor Haidar, Hashim
author_sort Ismail, Daut
title Voltage sag and the sensitive load
title_short Voltage sag and the sensitive load
title_full Voltage sag and the sensitive load
title_fullStr Voltage sag and the sensitive load
title_full_unstemmed Voltage sag and the sensitive load
title_sort voltage sag and the sensitive load
publisher Universiti Malaysia Sarawak (UNIMAS)
publishDate 2008
url http://dspace.unimap.edu.my/xmlui/handle/123456789/2081
_version_ 1643802686685970432
score 13.222552