Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor
International Conference on Man Machine Systems (ICoMMS 2012) organized by School of Mechatronic Engineering, co-organized by The Institute of Engineer, Malaysia (IEM) and Society of Engineering Education Malaysia, 27th - 28th February 2012 at Bayview Beach Resort, Penang, Malaysia.
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Working Paper |
Language: | English |
Published: |
Universiti Malaysia Perlis (UniMAP)
2012
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my/xmlui/handle/123456789/20503 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-20503 |
---|---|
record_format |
dspace |
spelling |
my.unimap-205032012-07-19T14:41:13Z Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor M. Shahiri-Tabarestani B. A. Ganji R. Sabbaghi-Nadooshan cmos_1945@yahoo.com baganji@nit.ac.ir R_sabbaghi@iauctb.ac.ir Deflection Mechanical sensitivity Intraocular pressure Sensitivity International Conference on Man Machine Systems (ICoMMS 2012) organized by School of Mechatronic Engineering, co-organized by The Institute of Engineer, Malaysia (IEM) and Society of Engineering Education Malaysia, 27th - 28th February 2012 at Bayview Beach Resort, Penang, Malaysia. To design mechanical pressure sensors, analysis of the deflection behavior of diaphragms is necessary. This paper describes effective factors on diaphragm's deflection and mechanical sensitivity of an Intraocular capacitive pressure sensor. Intraocular pressure sensors are important in detection and treatment of a fatal disease attributed to glaucoma. These pressure sensors have been designed to measure pressures in the range of 0 to 60 mmHg. This type of sensors operate by deformation of movable membrane for IOP diagnosis. So deflection of the diaphragm is a main factor for better performance of these pressure sensors. The principle of the paper is to Evaluate effective factors on sensor diaphragm and compare the results with the simulation using FEA method for a square diaphragm deflection. Generally, analysis of diaphragm behaviors are useful as they provide the designers better understanding and supplemental guidance. 2012-07-19T14:41:13Z 2012-07-19T14:41:13Z 2012-02-27 Working Paper http://hdl.handle.net/123456789/20503 en Proceedings of the International Conference on Man-Machine Systems (ICoMMS 2012) Universiti Malaysia Perlis (UniMAP) School of Mechatronic Engineering |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Deflection Mechanical sensitivity Intraocular pressure Sensitivity |
spellingShingle |
Deflection Mechanical sensitivity Intraocular pressure Sensitivity M. Shahiri-Tabarestani B. A. Ganji R. Sabbaghi-Nadooshan Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor |
description |
International Conference on Man Machine Systems (ICoMMS 2012) organized by School of Mechatronic Engineering, co-organized by The Institute of Engineer, Malaysia (IEM) and Society of Engineering Education Malaysia, 27th - 28th February 2012 at Bayview Beach Resort, Penang, Malaysia. |
author2 |
cmos_1945@yahoo.com |
author_facet |
cmos_1945@yahoo.com M. Shahiri-Tabarestani B. A. Ganji R. Sabbaghi-Nadooshan |
format |
Working Paper |
author |
M. Shahiri-Tabarestani B. A. Ganji R. Sabbaghi-Nadooshan |
author_sort |
M. Shahiri-Tabarestani |
title |
Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor |
title_short |
Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor |
title_full |
Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor |
title_fullStr |
Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor |
title_full_unstemmed |
Evaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensor |
title_sort |
evaluation of effective factors on diaphragm's deflection and mechanical sensitivity of an intraocular capacitive pressure sensor |
publisher |
Universiti Malaysia Perlis (UniMAP) |
publishDate |
2012 |
url |
http://dspace.unimap.edu.my/xmlui/handle/123456789/20503 |
_version_ |
1643793092650729472 |
score |
13.214268 |