A case study on electricity and chilled water production of a gas district cooling plant

Link to publisher’s homepage at http://www.myiem.org.my/

Saved in:
Bibliographic Details
Main Authors: Mohd. Amin, A. Majid, Syed Ihtsham-ul-Haq Gilani, Rangkuti, Chalilullah, Suhaimi, Hassan
Other Authors: mamin_amajid@petronas.com.my
Format: Article
Language:English
Published: The Institution of Engineers, Malaysia 2011
Subjects:
Online Access:http://dspace.unimap.edu.my/xmlui/handle/123456789/16251
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.unimap-16251
record_format dspace
spelling my.unimap-162512011-11-23T07:25:50Z A case study on electricity and chilled water production of a gas district cooling plant Mohd. Amin, A. Majid Syed Ihtsham-ul-Haq Gilani Rangkuti, Chalilullah Suhaimi, Hassan mamin_amajid@petronas.com.my Absorption chillers Chilled water Cogeneration Electric chillers Gas district cooling (GDC) Link to publisher’s homepage at http://www.myiem.org.my/ The paper presents the study on the production of electricity and chilled water of a gas district cooling (GDC) plant. The plant was designed as a cogeneration and GDC plant. The electricity was generated by two 4.2 MW gas turbines. The chilled water was produced by the combination of two unit absorption chillers and four unit electric chillers. The absorption chiller and electric chiller capacities are 1250 RT and 325 RT respectively. Electricity generated was supplied to the user as well as for in-plant consumption The designed standard was to operate the two turbines during the day and only one turbine during the night. While the absorption chillers were to be operated during the day, the electric chillers were to operate during the night for charging the thermal storage tank. The chilled water from the storage tank was designed to supplement the chilled water requirements during the day. From the analysis of two weeks operating data, one week for year 2004 and one week for year 2005, it was noted that variations occurred in terms of turbine operating hours and the chillers operating hours from that of the designed values. Preliminary findings indicated insufficient capacities of the electric chillers and the thermal storage tank were the main reason to the variations. 2011-11-23T07:25:50Z 2011-11-23T07:25:50Z 2006-09 Article p.20, 22, 26-27 0126-9909 http://www.myiem.org.my/content/iem_bulletin_2004_2007-163.aspx http://hdl.handle.net/123456789/16251 en Jurutera 2006 (9) The Institution of Engineers, Malaysia
institution Universiti Malaysia Perlis
building UniMAP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Perlis
content_source UniMAP Library Digital Repository
url_provider http://dspace.unimap.edu.my/
language English
topic Absorption chillers
Chilled water
Cogeneration
Electric chillers
Gas district cooling (GDC)
spellingShingle Absorption chillers
Chilled water
Cogeneration
Electric chillers
Gas district cooling (GDC)
Mohd. Amin, A. Majid
Syed Ihtsham-ul-Haq Gilani
Rangkuti, Chalilullah
Suhaimi, Hassan
A case study on electricity and chilled water production of a gas district cooling plant
description Link to publisher’s homepage at http://www.myiem.org.my/
author2 mamin_amajid@petronas.com.my
author_facet mamin_amajid@petronas.com.my
Mohd. Amin, A. Majid
Syed Ihtsham-ul-Haq Gilani
Rangkuti, Chalilullah
Suhaimi, Hassan
format Article
author Mohd. Amin, A. Majid
Syed Ihtsham-ul-Haq Gilani
Rangkuti, Chalilullah
Suhaimi, Hassan
author_sort Mohd. Amin, A. Majid
title A case study on electricity and chilled water production of a gas district cooling plant
title_short A case study on electricity and chilled water production of a gas district cooling plant
title_full A case study on electricity and chilled water production of a gas district cooling plant
title_fullStr A case study on electricity and chilled water production of a gas district cooling plant
title_full_unstemmed A case study on electricity and chilled water production of a gas district cooling plant
title_sort case study on electricity and chilled water production of a gas district cooling plant
publisher The Institution of Engineers, Malaysia
publishDate 2011
url http://dspace.unimap.edu.my/xmlui/handle/123456789/16251
_version_ 1643791121424318464
score 13.214268